Site Navigation

(MQQFC022) Quartz Rectangular Sample Cell, 40/10 mm Dual Path, 20 mL, Open at Both Ends

Weight150 g
SKU: MQQFC022

$600.00

In Stock

JGS1 quartz rectangular sample cell with a 40 mm primary path and 10 mm secondary path in the same open-ended chamber. This Four-Way Light design provides a 20 mL nominal capacity for setups that need two defined transmission directions and user-planned end mounting. Sold as 1 piece.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQFC022 is a JGS1 quartz rectangular sample cell for optical setups that need both a 40 mm path and a 10 mm path in one chamber body. Its open-at-both-ends format leaves the end support and sealing arrangement to your fixture, while the Four-Way Light layout gives access along two optical directions. With a 20 mL nominal capacity, it suits larger sample chambers where the cell, holder and liquid-handling approach are planned together.

Path Length
40 mm / 10 mm (dual path)
Sample Volume (Nominal)
20 mL
Opening Configuration
Open at Both Ends

Selection Specifications

Product KindSpecialized Cell
Cell TypeRectangular Sample Cell
Measurement ModeTransmission Spectroscopy
Path Length40 mm / 10 mm (dual path)
Light Transmission ConfigurationFour-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)20 mL
External Dimensions46 × 16 × 50 mm
Body Height50 mm
Base Dimensions46 × 16 mm
Internal Dimensions40 × 10 × 50 mm
MaterialQuartz
Material GradeJGS1
Fabrication MethodMolded 83
Opening ConfigurationOpen at Both Ends
Pack Quantity1 Piece

Choose this option

Choose MQQFC022 when your method uses one rectangular chamber but needs two stated transmission directions: 40 mm for the longer optical path and 10 mm for the secondary direction. The open-ended body is useful when you are building the surrounding support, sealing or filling arrangement yourself rather than buying a finished flow assembly.

View the English selection reference. Also available in the product gallery. Group photographs illustrate other options in the series.

What makes this option different

  • 40/10 mm dual path: one chamber body supports two defined beam directions, so you can design the setup around either optical length as required by the method.
  • Four-Way Light layout: optical access is available along two axis pairs, which is useful when the beam direction or observation geometry is part of the fixture design.
  • Open at both ends: sample access is direct from either end, and the final sealing or retention method is determined by your own assembly.
  • 20 mL nominal chamber volume: suited to a larger rectangular sample region rather than a very small-volume cell body.
  • Molded 83 fabrication: this construction is commonly chosen for methods involving organic solvents, while overall suitability still depends on the complete wetted assembly.

Structure and dimensions

Product dimensions for checking holder clearance and sample access.
Product dimensions for checking holder clearance and sample access.Open image ↗

Using this cell

Set the cell so the beam travels through the intended path length, and keep that orientation the same for blanks, standards and samples. If your procedure uses both optical directions, mark the fixture or mounting position so the 40 mm and 10 mm orientations are easy to repeat.

The chamber is open at both ends, so filling, draining and sample retention depend on the holder or sealing arrangement you add around the cell. The stated 20 mL is the nominal chamber capacity of the cell body, not a minimum working fill for a completed assembly.

First-use check

  1. Inspect the transmitting faces, edges and both end openings before installation.
  2. Check holder support and beam alignment in the intended measurement direction with a blank.
  3. Confirm filling, sealing and bubble control in the complete assembled setup before routine use.

Fit and optical alignment

Use the 46 × 16 × 50 mm outer dimensions to check holder clearance and support surfaces. The 40 × 10 × 50 mm internal dimensions describe the sample chamber and help you plan beam travel, sample access and end sealing, but they do not define the holder opening.

Z Height is not listed for this cell. If your instrument or fixture depends on a fixed beam height, check the actual beam position against your mounting geometry instead of assuming a standard cuvette alignment.

English selection reference
Selection reference ↗

Solvents and cleaning

This cell uses Molded 83 fabrication. It is often selected for organic-solvent methods, but the practical chemical limit depends on all wetted parts in the finished setup, especially if your end seals, tubing or fittings use other materials.

Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaning methods, and clean the optical faces gently to avoid scratching the transmitting surfaces.

Included with this option

1 quartz sample cell. The listed price is for one piece.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

If you need a different chamber size, path arrangement, outer dimensions, openings or fabrication target, please send your drawing or holder details through the contact page. Custom JGS1 quartz work is quoted separately from the listed SKU, with feasibility, quantity, price and production time reviewed case by case.

Additional information

Weight150 g

Reviews

There are no reviews yet.

Be the first to review “(MQQFC022) Quartz Rectangular Sample Cell, 40/10 mm Dual Path, 20 mL, Open at Both Ends”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare