(MQQFC035) Quartz Rectangular Sample Cell, 20 mm Path, 10 mL, Open at Both Ends

Weight150 g
SKU: MQQFC035

$257.00

In Stock

JGS1 quartz rectangular sample cell with a 20 mm optical path, Two-Way Light geometry and 10 mL nominal capacity. The body is open at both ends for use in your own holder, sealing method or sample-handling assembly. Supplied as 1 piece.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQFC035 is a JGS1 quartz rectangular sample cell for methods that use a 20 mm optical path and a larger chamber format. Its Two-Way Light geometry defines a single intended measurement direction, while the open-at-both-ends body leaves end support, filling and sealing to your own fixture. The nominal capacity is 10 mL in a 22 × 12 × 52 mm outer body.

Path Length
20 mm
Sample Volume (Nominal)
10 mL
Opening Configuration
Open at Both Ends

Selection Specifications

Product KindSpecialized Cell
Cell TypeRectangular Sample Cell
Measurement ModeTransmission Spectroscopy
Path Length20 mm
Light Transmission ConfigurationTwo-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)10 mL
External Dimensions22 × 12 × 52 mm
Body Height52 mm
Base Dimensions22 × 12 mm
Internal Dimensions10 × 20 × 52 mm
MaterialQuartz
Material GradeJGS1
Fabrication MethodMolded 83
Opening ConfigurationOpen at Both Ends
Pack Quantity1 Piece

Choose this option

Choose MQQFC035 when your setup is designed around a 20 mm path and you want a rectangular chamber with optical access through the intended two faces only. This format is useful when your method needs a larger sample chamber than compact micro-format cells, but you still want to build the final mounting and sealing arrangement around the bare quartz body.

View the English selection reference. Also available in the product gallery. Group photographs illustrate other options in the series.

What makes this option different

  • 20 mm optical path suits methods that require a longer defined path length.
  • Two-Way Light geometry limits optical access to the intended pair of transmitting faces.
  • 10 mL nominal capacity provides a larger chamber format within a rectangular body.
  • Open-at-both-ends construction leaves sample filling, retention and end sealing to your own setup.

Structure and dimensions

Product dimensions for checking holder clearance and sample access.
Product dimensions for checking holder clearance and sample access.Open image ↗

Using this cell

Install the cell so the beam travels through the intended 20 mm path and keep the same orientation for blanks and samples. For liquid work, define the sealing, filling and bubble-removal procedure in the holder you actually use, because the supplied cell body does not include built-in fittings or closures.

The listed 10 mL value is the nominal chamber capacity. It should not be read as the minimum working fill, since retained volume and usable fill level depend on the fixture, seals and any added hardware.

First-use check

  1. Inspect the optical faces, open ends and edges before installation.
  2. Confirm beam alignment in the mounted fixture with a blank before routine measurements.
  3. For liquid use, verify that your sealing arrangement retains the sample and keeps bubbles or exterior droplets out of the beam area.

Fit and optical alignment

Use the 22 × 12 × 52 mm outer dimensions to check fixture clearance and support geometry. The 10 × 20 × 52 mm internal dimensions describe the chamber and path direction, not the beam-center height in your instrument.

Z Height is not listed for this model, so beam matching should be checked from the mounted geometry rather than assumed from body height alone. Support the cell evenly and avoid clamping across the transmitting faces.

English selection reference
Selection reference ↗

Solvents and cleaning

This cell uses Molded 83 construction. That fabrication is commonly selected for organic-solvent methods and heated applications, but the chemical suitability of the full assembly also depends on any added seals, fittings or support materials.

Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaners. Clean the optical faces gently with non-abrasive optical tissue and a cleaning liquid suitable for your method.

Included with this option

1 rectangular sample cell, SKU MQQFC035. The listed price is for one piece.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We can review custom JGS1 quartz versions for changes to path length, body size, chamber layout, capacity, closures or connection details. Send your drawing or holder details, critical dimensions, sample conditions and required quantity through our contact page.

Additional information

Weight150 g

Reviews

There are no reviews yet.

Be the first to review “(MQQFC035) Quartz Rectangular Sample Cell, 20 mm Path, 10 mL, Open at Both Ends”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare