Quartz rectangular sample cell with a 10 mm optical path, 43 mL nominal capacity and an open-at-both-ends body. Its long 86 mm chamber suits setups that need a straight rectangular sample space and separate end sealing or mounting. Sold as 1 piece.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQFC045 is a JGS1 quartz rectangular sample cell for transmission measurements with a 10 mm optical path and a long open-through chamber. Its 43 mL nominal capacity and 86 mm body length make it useful when you need a defined rectangular sample space but want to set the end sealing, filling and support arrangement in your own fixture. The straight exterior also gives a clear envelope for holder design.

Path Length
10 mm
Sample Volume (Nominal)
43 mL
Opening Configuration
Open at Both Ends

Selection Specifications

Product KindSpecialized Cell
Cell TypeRectangular Sample Cell
Measurement ModeTransmission Spectroscopy
Path Length10 mm
Light Transmission ConfigurationTwo-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)43 mL
External Dimensions54 × 14 × 86 mm
Body Height86 mm
Base Dimensions54 × 14 mm
Internal Dimensions50 × 10 × 86 mm
MaterialQuartz
Material GradeJGS1
Fabrication MethodMolded 83
Opening ConfigurationOpen at Both Ends
Pack Quantity1 Piece

Choose this option

Choose this cell when your setup needs a 10 mm transmission path in a rectangular quartz body and access from both ends of the chamber. It is a good fit for custom assemblies where the cell body is one part of a larger holder or sealing arrangement, rather than a ready-finished cuvette with built-in closures.

View the English selection reference.

What makes this option different

  • 10 mm optical path: suitable for methods built around a standard transmission length.
  • Open at both ends: you can design the end sealing, filling and drainage around your own assembly.
  • Long rectangular chamber: the internal 50 × 10 × 86 mm geometry provides a straight sample space through the full body height.
  • Defined outer body: the 54 × 14 × 86 mm exterior helps when planning holder clearance and support surfaces.

Structure and dimensions

Product dimensions for checking holder clearance and sample access.
Product dimensions for checking holder clearance and sample access.Open image ↗

Using this cell

Mount the cell so the beam passes across the 10 mm path. Because the body is open at both ends, the practical loading and retention method comes from the separate end treatment used in your system.

For liquid work, establish how the chamber will be filled, vented and drained before routine measurements. The 43 mL figure is a nominal cell volume for the body, not a minimum working volume, so the actual fill condition should be checked in the finished assembly.

First-use check

  1. Inspect the optical faces and end edges for chips, residue or handling marks.
  2. Confirm that the holder supports the body evenly and keeps the beam on the intended path.
  3. Run a blank in the finished assembly to check filling, drainage and bubble removal.

Fit and optical alignment

Use the 54 × 14 × 86 mm external dimensions for holder clearance and support design. The 50 × 10 × 86 mm internal dimensions describe the chamber itself, not the opening required in your fixture.

Z Height is not listed for this cell, so beam-height matching should be checked from the actual mounted position rather than assumed from overall body height alone. Support the body evenly and avoid concentrated clamping force across the transmitting faces.

English selection reference
Selection reference ↗

Solvents and cleaning

This cell is listed with Molded 83 fabrication. In use, choose the sample-contact and cleaning conditions for the complete assembled setup, including any seals, fittings or supports added around the open ends.

Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaning methods. Clean the optical faces gently with suitable non-abrasive materials, and check any process liquid or cleaning solvent against the full assembly you intend to build.

Included with this option

1 rectangular sample cell. The listed price is for one piece.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We coordinate custom JGS1 quartz versions for changes to path length, chamber size, exterior envelope, openings and related holder requirements. Send your drawing or labelled sketch, critical dimensions, sample conditions and target quantity through the contact page so the mounting and sealing arrangement can be reviewed around your application.

Additional information

Weight150 g

Reviews

There are no reviews yet.

Be the first to review “(MQQFC045) Quartz Rectangular Sample Cell, 10 mm Path, 43 mL, Open at Both Ends”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare