Quartz rectangular sample cell with a 10 mm optical path, Four-Way Light access and 2.4 mL nominal capacity. Its open-at-both-ends JGS1 quartz body provides a 12.5 × 12.5 × 24 mm outer envelope for custom holders, sealing arrangements or built-in assemblies. Sold as 1 piece.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQFC038 is a JGS1 quartz rectangular sample cell for UV/Vis work from 200 to 2500 nm. It combines a full 10 mm optical path with Four-Way Light access in an open-ended body, making it useful when you want a standard rectangular sample chamber but need to integrate it into your own holder, sealing arrangement or fluid-handling layout. The nominal capacity is 2.4 mL, with a 10 × 10 × 24 mm internal chamber inside a 12.5 × 12.5 × 24 mm exterior.

View the English selection reference. Group photographs in the gallery may show related options in the series.

Path Length
10 mm
Sample Volume (Nominal)
2.4 mL
Opening Configuration
Open at Both Ends

Selection Specifications

Product KindSpecialized Cell
Cell TypeRectangular Sample Cell
Measurement ModeTransmission Spectroscopy
Path Length10 mm
Light Transmission ConfigurationFour-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)2.4 mL
External Dimensions12.5 × 12.5 × 24 mm
Body Height24 mm
Base Dimensions12.5 × 12.5 mm
Internal Dimensions10 × 10 × 24 mm
MaterialQuartz
Material GradeJGS1
Fabrication MethodMolded 83
Opening ConfigurationOpen at Both Ends
Pack Quantity1 Piece

Choose this option

Choose MQQFC038 when your method is built around a 10 mm path but a finished capped cuvette or ready-connected flow cell is not the right format. The square 10 × 10 mm chamber and four-way optical access suit custom fixtures where beam direction, side access or the filling arrangement are set by your own assembly.

What makes this option different

  • 10 mm optical path in a rectangular open-ended sample chamber.
  • Four-Way Light configuration for optical access through two face pairs.
  • 2.4 mL nominal capacity with a 10 × 10 × 24 mm internal chamber.
  • Open at both ends for custom mounting, sealing or integration rather than capped bench use.

Structure and dimensions

Product dimensions for checking holder clearance and sample access.
Product dimensions for checking holder clearance and sample access.Open image ↗

Using this cell

This cell body does not include built-in closures or fluid connections. For liquid use, define how the sample will be filled, retained and emptied at the two open ends before you install it in routine work.

Align the beam to the 10 mm path and keep the same orientation for blank and sample. The stated 2.4 mL is the nominal chamber volume; your completed setup may need a different fill amount depending on how the ends are handled in the fixture.

First-use check

  1. Inspect the optical faces, end edges and chamber opening for chips, residue or handling marks.
  2. Place the cell in the intended holder and confirm stable support before adding sample.
  3. Run a blank and check filling, emptying and bubble control in the final orientation.

Fit and optical alignment

Use the 12.5 × 12.5 × 24 mm outer dimensions to check holder clearance, and the 10 × 10 × 24 mm inner dimensions only to understand chamber space. The body should be supported across suitable contact areas rather than clamped by local pressure on the optical faces or end edges.

Z Height is not specified for this SKU. If your instrument or fixture has a fixed beam height, verify the beam position in the actual mounted geometry instead of assuming alignment from the 24 mm body height alone.

English selection reference
Selection reference ↗

Solvents and cleaning

Molded 83 is the MQ fabrication designation for this optical-contact quartz construction. It is a suitable selection direction for methods that may involve organic solvents or temperature, while the full assembly still needs to match your actual liquid, concentration, temperature and contact time.

Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaning methods. If your process adds seals, fittings or prolonged liquid contact, ask us to review the complete conditions before ordering.

Included with this option

1 rectangular sample cell, SKU MQQFC038. The listed price is for one piece.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We can review custom JGS1 quartz projects for changes to path length, body size, nominal volume, optical access, Z Height and end-interface design. Send your drawing or holder information, sample conditions, quantity and delivery target through this contact page.

Additional information

Weight80 g

Reviews

There are no reviews yet.

Be the first to review “(MQQFC038) Quartz Rectangular Sample Cell, 10 mm Path, 2.4 mL, Open at Both Ends”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare