(MQQFC040) Quartz Rectangular Sample Cell, 10 mm Path, 2.8 mL, Open at Both Ends
Description
MQQFC040 is a JGS1 quartz rectangular sample cell for UV/Vis work from 200 to 2500 nm. It combines a 10 mm optical path with Four-Way Light access in an open-ended body, making it useful when you need a standard rectangular transmission chamber but want to define the end support, sealing and sample handling in your own fixture. The nominal capacity is 2.8 mL, with a 10 × 10 × 28 mm internal chamber inside a 12.5 × 12.5 × 28 mm exterior.
View the English selection reference. Group photographs in the gallery may show related options in the series.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 2.8 mL
- Opening Configuration
- Open at Both Ends
Selection Specifications
| Product Kind | Specialized Cell |
|---|---|
| Cell Type | Rectangular Sample Cell |
| Measurement Mode | Transmission Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 2.8 mL |
| External Dimensions | 12.5 × 12.5 × 28 mm |
| Body Height | 28 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Internal Dimensions | 10 × 10 × 28 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Fabrication Method | Molded 83 |
| Opening Configuration | Open at Both Ends |
| Pack Quantity | 1 Piece |
Choose this option
Choose MQQFC040 when you need a 10 mm path in an open rectangular cell body rather than a complete cuvette with a cap or a ready-connected flow assembly. The longer 28 mm chamber length increases the nominal chamber volume compared with shorter bodies of the same path and cross-section, while Four-Way Light access supports setups that need optical access from two face pairs.
What makes this option different
- 10 mm optical path in a rectangular open-ended sample chamber.
- Four-Way Light configuration for optical access through two opposed face pairs.
- 2.8 mL nominal capacity with a 10 × 10 × 28 mm internal chamber.
- Open at both ends so the holder or assembly defines filling, retention and end treatment.
Structure and dimensions

Using this cell
Fill and retain the sample according to the holder, sealing method or surrounding assembly used in your setup. Because the body is open at both ends, the practical filling procedure, bubble control and emptying method depend on how the cell is installed rather than on the cell body alone.
During measurement, keep the optical faces clean and use a consistent orientation between blank and sample. The 2.8 mL figure is the nominal chamber volume, not a minimum working volume, so the final usable fill condition should be established in the mounted setup.
First-use check
- Inspect the cell for chips, edge damage and contamination on the optical faces.
- Test the fit in the intended holder before introducing valuable samples.
- Run a blank in the final mounted orientation and confirm that filling, sealing and bubble removal work as expected.
Fit and optical alignment
Check holder clearance against the 12.5 × 12.5 × 28 mm outer body, and use the 10 × 10 × 28 mm inner dimensions only for the sample chamber. Match your fixture to an open-ended rectangular body rather than to a capped cuvette format, and support the cell across suitable contact areas instead of local pressure on faces or edges.
Z Height is not stated for this SKU. If your instrument or fixture requires a defined beam-center position, verify alignment in the real mounted geometry rather than assuming it from overall body height alone.

Solvents and cleaning
This cell uses Molded 83 construction. This is a suitable selection direction for methods that may involve organic solvents or temperature, while suitability still depends on the complete assembled setup, including any seals, fittings or end supports used with this open cell body.
Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaning methods, and clean the optical faces gently with non-abrasive materials.
Included with this option
1 MQQFC040 rectangular sample cell. The listed price is for one piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different fit, please send your required optical path, external envelope, holder details, beam position, sealing method and sample conditions. Custom work is generally discussed in JGS1 quartz, with feasibility, quantity, price and timing confirmed for the project. You can also use this contact page and include SKU MQQFC040 with your drawing or fixture details.
Additional information
| Weight | 50 g |
|---|
You must be logged in to post a review.








Reviews