(MQQFC036) Quartz Rectangular Sample Cell, 20/10 mm Dual Path, 10 mL, Open at Both Ends
Description
MQQFC036 combines two stated optical path directions, 20 mm and 10 mm, in one JGS1 quartz rectangular sample cell. Its Four-Way Light layout gives optical access from four sides, so the same body can be used in either of the specified beam orientations when your fixture supports that arrangement. The cell is open at both ends and has a 10 mL nominal capacity.
- Path Length
- 20 mm / 10 mm (dual path)
- Sample Volume (Nominal)
- 10 mL
- Opening Configuration
- Open at Both Ends
Selection Specifications
| Product Kind | Specialized Cell |
|---|---|
| Cell Type | Rectangular Sample Cell |
| Measurement Mode | Transmission Spectroscopy |
| Path Length | 20 mm / 10 mm (dual path) |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 10 mL |
| External Dimensions | 22 × 12 × 52 mm |
| Body Height | 52 mm |
| Base Dimensions | 22 × 12 mm |
| Internal Dimensions | 20 × 10 × 52 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Fabrication Method | Molded 83 |
| Opening Configuration | Open at Both Ends |
| Pack Quantity | 1 Piece |
Choose this option
Choose MQQFC036 when you want one rectangular cell body that supports two defined path directions instead of a single fixed path. This format is useful when your method, holder or optical setup needs flexibility between the 20 mm and 10 mm directions, while still using the same chamber body and overall outer dimensions.
View the English selection reference. Also available in the product gallery. Group photographs illustrate other options in the series.
What makes this option different
- Dual 20/10 mm path directions allow one cell body to be used in two stated optical orientations.
- Four-Way Light configuration gives optical access from four sides of the rectangular body.
- 10 mL nominal capacity provides a larger chamber format than micro-volume cells.
- Open at both ends leaves filling, retention and sealing to your own fixture or assembly.
Structure and dimensions

Using this cell
Mount the cell with the intended beam direction clearly identified, and keep the same orientation for blank and sample measurements. If your procedure uses the 20 mm direction in one method and the 10 mm direction in another, document that orientation in the setup so the selected path remains consistent.
The nominal 10 mL capacity describes the chamber volume, not the minimum working fill. Actual working volume depends on how the cell is supported and sealed in your holder, and on any additional parts added around the supplied quartz body.
First-use check
- Inspect all optical faces, end edges and open ends before installation.
- Mount the cell and verify beam position for the specific path direction you plan to use.
- For liquid use, confirm that your sealing and filling method retains the sample properly and leaves the optical path free of bubbles.
Fit and optical alignment
Use the 22 × 12 × 52 mm outer dimensions to check holder clearance. The 20 × 10 × 52 mm internal dimensions explain the chamber shape and the two stated path directions, but they do not establish beam-center height for your instrument.
Z Height is not listed for this model. If your setup depends on a defined beam height, confirm that from the mounted geometry rather than assuming it from overall body height alone.

Solvents and cleaning
This cell uses Molded 83 construction. That fabrication is commonly selected for organic-solvent methods and heated applications, but the complete setup should be reviewed as an assembly if you add seals, fittings or support materials around the cell.
Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaners. Clean optical faces gently with non-abrasive optical tissue and a cleaning liquid suitable for your method.
Included with this option
1 rectangular sample cell, SKU MQQFC036. The listed price is for one piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review custom JGS1 quartz versions for changes to path length, dual-path geometry, body dimensions, capacity, closures or connection details. Send your drawing or holder details, critical dimensions, sample conditions and required quantity through our contact page.
Additional information
| Weight | 54 g |
|---|
You must be logged in to post a review.








Reviews