(MQQFC108) JGS1 Quartz Counting Flow Cell, 0.05 mm Path, 4 µL

Weight50 g
SKU: MQQFC108

$359.00

In Stock

JGS1 quartz counting flow cell with a 0.05 mm optical path and 4 µL nominal capacity in a 30 × 4 × 15 mm optical body. Two opposed tubes, sized at 1.5 mm OD / 1 mm ID, connect the small sample region to your flow circuit. Two opposing optical faces support transmission measurement. One cell supplied.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQFC108 is a JGS1 quartz counting flow cell for UV/Vis setups that need a very short 0.05 mm optical path in a compact in-line format. Its 4 µL nominal capacity and two opposed fluid tubes make it useful when the optical path, sample region and connection size all need to be planned together around a small installed cell.

Path Length
0.05 mm
Sample Volume (Nominal)
4 µL
Opening Configuration
Two Opposed Fluid Tubes

Selection Specifications

Product KindFlow Cell
Cell TypeCounting Flow Cell
Measurement ModeUV/Vis Spectroscopy
Path Length0.05 mm
Light Transmission ConfigurationTwo-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)4 µL
Cell Body Dimensions30 × 4 × 15 mm
Body Height15 mm
Base Dimensions30 × 4 mm
MaterialQuartz
Material GradeJGS1
Port Count2
Tube Outer Diameter (OD)1.5 mm
Tube Inner Diameter (ID)1 mm
Fabrication MethodStandard 80
Opening ConfigurationTwo Opposed Fluid Tubes
Port LayoutEnd/side connection at the left in the referenced original; Opposite end/side connection at the right in the referenced original
Pack Quantity1 Piece
Package Contents1 × Quartz Counting Flow Cell

Choose this option

Choose MQQFC108 when your method is built around a fixed 0.05 mm transmission path and a small integrated flow cell rather than an open sample chamber. This option suits layouts where the tube size matters as much as the optical path, and where you want a compact quartz body with direct end-to-end fluid connection.

What makes this option different

  • 0.05 mm optical path for methods that require an extremely short fixed transmission length.
  • 4 µL nominal capacity for a small sample region within the flow circuit.
  • Two-Way Light layout for straight-through optical measurement across the defined path.
  • Two opposed fluid tubes with 1.5 mm outer diameter and 1 mm inner diameter for connection planning.

Using this cell

Install the cell with the body supported and avoid putting side load on the projecting tubes during tubing connection. Fill the channel gradually, then inspect the optical region before measurement so that visible bubbles and exterior droplets are cleared.

The 4 µL figure is the nominal cell volume. It should be used for circuit planning, not as a stated minimum working volume. If your process depends on a defined pressure range or the lowest usable fill, those limits need to be checked on the full assembled system.

First-use check

  1. Inspect the optical faces and tube ends before installation.
  2. Check holder fit and beam position with a suitable blank.
  3. Confirm that the optical region fills cleanly and remains free of visible bubbles before measurement.

Fit and optical alignment

View the English selection reference.

The stated 30 × 4 × 15 mm dimensions describe the optical body only. They do not include the full installed envelope with the projecting tubes, so leave additional space for tubing approach, bend radius and any external fittings.

Z Height is not stated for this SKU. If your holder or instrument depends on a defined beam-center height, check that separately before ordering instead of using the 15 mm body height as a substitute.

Gallery series photographs illustrate the shared cell format. The ordered path length and nominal capacity are the values stated for MQQFC108.

English selection reference
Selection reference ↗

Solvents and cleaning

Standard 80 is an adhesive-bonded quartz construction suited to routine room-temperature aqueous samples and buffers. Avoid organic sample solvents and organic cleaning agents with this bonded assembly. If your method involves organic solvents or heated treatment, ask about a more suitable alternative before ordering.

Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Clean the exterior optical faces gently with non-abrasive optical tissue.

Included with this option

1 Quartz Counting Flow Cell. The listed price is for 1 piece.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We coordinate custom JGS1 quartz production for changes to path length, body dimensions, optical layout, tube connections and other installation-related details. Send your drawing or holder information, sample conditions, required quantity and delivery target. Prototype batches typically involve 2–4 cells, with final feasibility, specifications, price and timing confirmed in quotation. Send a product-selection enquiry with SKU MQQFC108.

Additional information

Weight50 g

Reviews

There are no reviews yet.

Be the first to review “(MQQFC108) JGS1 Quartz Counting Flow Cell, 0.05 mm Path, 4 µL”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare