(MQQFC018) Quartz Rectangular Sample Cell, 3 mm Path, 3.6 mL, Open at Both Ends
Description
MQQFC018 is a JGS1 quartz rectangular sample cell with a 3 mm optical path and a 3.6 mL nominal capacity. The body is open at both ends and uses a Two-Way Light layout, making it useful when you need a defined transmission path in a straight rectangular chamber but want to handle end support and sealing in your own fixture. The chamber dimensions and the outer envelope are both straightforward to review during holder design.
View the English selection reference. Also available in the product gallery. Group photographs illustrate other options in the series.
- Path Length
- 3 mm
- Sample Volume (Nominal)
- 3.6 mL
- Opening Configuration
- Open at Both Ends
Selection Specifications
| Product Kind | Specialized Cell |
|---|---|
| Cell Type | Rectangular Sample Cell |
| Measurement Mode | Transmission Spectroscopy |
| Path Length | 3 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 3.6 mL |
| External Dimensions | 40 × 8 × 40 mm |
| Body Height | 40 mm |
| Base Dimensions | 40 × 8 mm |
| Internal Dimensions | 30 × 3 × 40 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Fabrication Method | Standard 80 |
| Opening Configuration | Open at Both Ends |
| Pack Quantity | 1 Piece |
Choose this option
Choose MQQFC018 when your method needs a 3 mm path in an open rectangular quartz chamber rather than a capped cuvette format. It suits custom sample handling, clamping or sealing arrangements where you want direct access to the chamber ends and a simple body shape for integration into a holder.
What makes this option different
- 3 mm optical path: a defined transmission distance for methods built around this path length.
- Open at both ends: the cell body leaves end retention and sealing to your assembly instead of providing an integrated closure.
- 3.6 mL nominal capacity: paired with a straight rectangular chamber for straightforward filling and sample positioning in a custom setup.
- Defined inner and outer geometry: the 30 × 3 × 40 mm chamber sits inside a 40 × 8 × 40 mm body, so chamber size and holder clearance can be checked separately.
Structure and dimensions

Using this cell
Mount the cell so the beam passes through the 3 mm path across the transmitting faces. Keep the same orientation for blank and sample measurements, especially if your holder also defines how the open ends are sealed or supported.
The 3.6 mL figure is the nominal chamber capacity. Your actual filling routine, retained liquid and usable level depend on the seals, supports or connected parts used in the finished assembly.
First-use check
- Inspect the optical faces and end edges for chips, residue or handling marks.
- Place the cell in the holder and confirm even support without twisting or local pressure.
- Run a blank with your intended sealing or retention method and check beam clearance and bubble behaviour.
Fit and optical alignment
Use the full 40 × 8 × 40 mm outer size when checking holder clearance. The internal 30 × 3 × 40 mm dimensions describe the sample chamber only, so they should not be used as the external fit size.
Z Height is not specified for this SKU. If your instrument or holder depends on a fixed beam-center height, check that position in the mounted arrangement rather than assuming it from the overall body height.

Solvents and cleaning
This cell uses Standard 80 adhesive-bonded quartz construction. It is generally suited to routine room-temperature aqueous samples and buffers. Avoid organic samples and organic cleaning solvents on the bonded assembly.
Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaning methods. Clean the optical faces gently with suitable non-abrasive laboratory wipes.
Included with this option
1 MQQFC018 rectangular sample cell. The listed price is for one piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different path length, chamber size, outer envelope or interface arrangement, send your drawing or holder details for review. Custom projects generally use JGS1 quartz, with feasibility and final specifications confirmed for the specific requirement.
Send a product-selection enquiry with SKU MQQFC018, your holder or sealing concept, sample conditions and required quantity.
Additional information
| Weight | 77 g |
|---|
You must be logged in to post a review.











Reviews
There are no reviews yet.