(MQQFC023) Quartz Rectangular Sample Cell, 3 mm Path, 3.6 mL, Open at Both Ends
Description
MQQFC023 is a JGS1 quartz rectangular sample cell with a 3 mm optical path in a compact open-ended body. The long rectangular chamber and Two-Way Light layout suit transmission setups that only need one stated beam direction, while the open ends leave filling and sealing to your own holder or fixture. Its 3.6 mL nominal capacity fits methods that want a defined short path without a large chamber volume.
- Path Length
- 3 mm
- Sample Volume (Nominal)
- 3.6 mL
- Opening Configuration
- Open at Both Ends
Selection Specifications
| Product Kind | Specialized Cell |
|---|---|
| Cell Type | Rectangular Sample Cell |
| Measurement Mode | Transmission Spectroscopy |
| Path Length | 3 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 3.6 mL |
| External Dimensions | 40 × 9 × 40 mm |
| Body Height | 40 mm |
| Base Dimensions | 40 × 9 mm |
| Internal Dimensions | 30 × 3 × 40 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Fabrication Method | Standard 80 |
| Opening Configuration | Open at Both Ends |
| Pack Quantity | 1 Piece |
Choose this option
Choose MQQFC023 when your method is built around a 3 mm transmission path and you want a simple rectangular cell body rather than a preassembled cuvette with caps or ports. The open-at-both-ends geometry is useful when the end sealing, sample retention and mounting arrangement are already defined by your fixture.
What makes this option different
- 3 mm optical path: suited to methods that specify this shorter transmission distance rather than a standard longer path.
- Two-Way Light configuration: the cell is arranged for one transmission axis pair, which keeps the optical layout straightforward.
- Open at both ends: you load, retain and seal the sample through your own fixture instead of relying on an included closure.
- 30 × 3 × 40 mm internal chamber: gives a long rectangular sample region within a narrow 3 mm path.
- 3.6 mL nominal capacity: smaller than larger open rectangular cells, while still providing a full-height chamber body.
- Standard 80 fabrication: adhesive-bonded quartz construction is generally selected for room-temperature aqueous samples and buffers rather than organic-solvent cleaning routines.
Structure and dimensions

Using this cell
Use this cell in a holder that supports the rectangular body and controls how liquid is retained at both ends. Because the body has no built-in closure or porting, plan the filling direction, end sealing and bubble-removal approach as part of the complete setup.
Align the beam across the 3 mm path and keep the orientation consistent between blank and sample measurements. The stated 3.6 mL is the nominal chamber volume of the cell body; the working fill in your assembled setup depends on how the ends are supported and sealed.
First-use check
- Inspect the optical faces and end edges for chips, residue or handling marks.
- Test the fit in your holder before introducing sample.
- Run a blank to verify beam alignment, sample retention and bubble control in the assembled setup.
Fit and optical alignment
Check the 40 × 9 × 40 mm external body against your holder opening and support surfaces. The 30 × 3 × 40 mm internal dimensions describe the sample chamber itself and help you assess beam travel and sample space, but they are not the holder-fit dimensions.
Z Height is not stated for this cell. If your instrument has a fixed beam position or a close-tolerance holder, verify the actual mounting geometry before ordering rather than assuming a standard cuvette beam center.

Solvents and cleaning
This cell is listed as Standard 80 with adhesive-bonded quartz construction. It is generally suited to room-temperature aqueous samples and buffers. If your method involves organic solvents, heated cleaning or longer exposure to demanding chemicals, review the suitability of the bonded assembly before ordering.
Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis, organic cleaning solvents and abrasive cleaning methods, and wipe the transmitting faces gently with non-abrasive materials.
Included with this option
1 rectangular sample cell, SKU MQQFC023. The listed price is for one piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different body size, path length, opening arrangement or holder interface, send your drawing or labelled sketch with the critical dimensions, beam position, sample conditions and target quantity. Custom JGS1 quartz projects are quoted case by case.
Send a product-selection enquiry with SKU MQQFC023 and your holder or sealing details.
Additional information
| Weight | 86 g |
|---|
You must be logged in to post a review.