4 / 25 mm Particle-Analysis Cell: Two Optical Directions and a Sloped Side
CUSTOM DESIGN GUIDE · MQQPA018
MQQPA018 is a quartz particle-analysis cell with 4 mm and 25 mm optical directions and a sloped, frosted side feature. The chamber and the outside body have different outlines. This makes it a useful reference when viewing direction and instrument positioning need to be designed together.

Use and purpose · Specifications · In practice · Custom example · Buy or enquire
The chamber gives the two paths their meaning
The recorded inner space is 25 × 4 × 57 mm, within a 35 × 12 × 63 mm outside body. The 25 mm and 4 mm chamber directions explain the dual-path designation. The larger outside dimensions describe the structure around that sample space.
For a proposed particle-observation arrangement, the illumination and collection directions establish how the chamber is used. Merely stating “dual path” leaves out that relationship. The selected direction also determines which surrounding surfaces must remain outside the optical route.
MQQPA018 configuration
Keep the sloped side in the installation view
The sloped, frosted feature is part of the cell's identity. Replacing it with a generic rectangle on the holder drawing loses a potentially important contact or clearance relationship. A section through the actual support shows where the body meets the fixture.
The 63 mm outside height and 57 mm inner height refer to different boundaries. Neither is a substitute for the height of the beam above the support. Using a shared datum links the chamber, side feature and observation position.
Loading is another direction to leave open
The top opening allows sample access from above. A layout can expose the optical faces and still leave an awkward filling route if an upper bracket sits too close to the opening. Loading and removal therefore belong beside the side and front views.
This form is relevant when the unequal chamber directions and side profile serve a defined instrument layout. A simple straight-sided cell may be easier to hold where those features serve no purpose; a matching outside height alone does not make the two forms interchangeable.
A custom example: change the side contact, keep the chamber
ILLUSTRATIVE DESIGN EXAMPLE
Suppose a new fixture uses the same observation directions but contacts the sloped side at a different place. The proposal can retain the 4 mm and 25 mm chamber directions and define the new support region from the fixture section. The slope and contact are dimensioned as part of that proposal rather than estimated from an angled image.
Order the listed configuration or discuss a change
View MQQPA018 and current pricing. For a custom version, send a labelled sketch that separates the features to retain from the changes you want.
Reference MQQPA018 with the light directions, support section and required sample access. Mark the chamber to retain and the side contact to adapt. Add sample conditions, quantity, destination and requested date.