150 µL Quartz Counting Flow Cell with Stainless-Steel Tubes
CUSTOM DESIGN GUIDE · MQQFC127
MQQFC127 combines a nominal 150 µL chamber and 2 mm path in a 20 × 20 × 3 mm quartz body. Opposed stainless-steel tubes connect to the sample region. It is a compact reference for a counting or observation setup where both the field of view and the fluid interfaces are tightly constrained.

Use and purpose · Specifications · In practice · Custom example · Buy or enquire
The small body is the centre of a connected sample route
A counting or imaging arrangement needs the sample in a defined observation region while leaving a route for delivery and removal. This cell provides the quartz body and two opposed tube interfaces for such a proposed arrangement. The optical or counting method itself is defined by the surrounding instrument.
The 2 mm path and 150 µL nominal capacity describe the reference chamber. Neither value sets a count accuracy or a complete sample budget. External lines, filling and exchange add their own volume and operating steps.
MQQFC127 configuration
The metal tubes extend beyond the quartz square
The stainless-steel tubes are 2 mm outside and 1.4 mm inside diameter, with a 17 mm projection labelled at the indicated end. The mating connector responds to the outside tube; the bore is the passage inside it. Both are useful dimensions for the connection drawing.
The installed footprint includes those projections, the connectors and the lines beyond them. A holder sized only around the 20 mm body can leave the tube ends too close to a wall or outside the accessible part of the fixture.
Treat the cell as a bonded assembly
The reference is an assembled cell, not a set of plates and tubes intended to be separated for loading. Filling and cleaning therefore use the available passage through the unit. This distinguishes it from a demountable counting chamber opened between samples.
Sample contact also includes the stainless-steel tubes, not only the quartz viewing body. The sample and cleaning procedure belong to the complete arrangement. A material choice for the window alone cannot describe every wetted interface.
A custom example: shorten the connection envelope
ILLUSTRATIVE DESIGN EXAMPLE
Suppose a neighbouring wall limits the space beyond one tube while the central observation region already fits. A proposed version can retain the 2 mm chamber and define a different tube projection or mating approach. The change is specified for a new assembly rather than as an instruction to cut the existing tube.
Order the listed configuration or discuss a change
View MQQFC127 and current pricing. For a custom version, send a labelled sketch that separates the features to retain from the changes you want.
Reference MQQFC127 with the observation field, holder and both connector envelopes. Mark the tube projection or interface to change, then include sample-contact requirements, loading and cleaning method, quantity, destination and requested date.