(C104CQF) Quartz Fluorescence Cuvette, 10 mm Path, 3.5 mL
Description
C104CQF is a JGS1 quartz fluorescence cuvette with a 10 mm optical path, Four-Way Light access and 3.5 mL nominal capacity. Its rectangular body gives optical access from all four side faces, and the included lid covers the open top during handling and measurement. This option suits routine filled-volume fluorescence work where you need side access around the sample region rather than a restricted two-face transmission layout.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 3.5 mL
- Closure Type
- Lid
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Fluorescence Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 3.5 mL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Included | Yes |
| Fabrication Method | Molded 0.01 |
Choose this option
Choose C104CQF when your method uses a 10 mm fluorescence cuvette and benefits from optical access on all four sides of the cell body. The 3.5 mL nominal capacity suits filled liquid measurements, while the separate uncapped body size helps you check holder seating and leave additional space above the cell for the lid.
What makes this option different
- 10 mm optical path: match the measurement method to this transmission distance and align the beam through the sample region.
- Four-Way Light: use the available side faces to arrange illumination and collection in a measurement geometry suitable for this cell.
- 3.5 mL nominal capacity: plan the working fill and beam footprint together so liquid covers the illuminated region; nominal capacity is not a minimum working fill.
- Accompanying closure: cover the opening after preparation and allow room to remove it; no pressure or leak-tight rating is specified.
- Molded 0.01 option: review the required optical-path tolerance and measurement conditions for your order when precision is central to the method.
Using this cell
Fill the cuvette so the measurement zone is properly covered and keep the optical faces clean in the beam area. When your fluorescence setup uses one pair of faces for excitation and another for observation or collection, keep the same orientation between blank and sample runs.
The lid covers the top during handling and use, but it should not be treated as a pressure seal. The 3.5 mL figure is the nominal capacity, not a minimum working volume, so the actual fill level should be checked in your instrument setup.
First-use check
- Inspect the optical faces for residue, chips or fingerprints before use.
- Test the uncapped body in your holder and confirm lid clearance separately.
- Run your normal blank or baseline check with the same orientation you will use for samples.
Fit and optical alignment
The stated 12.5 × 12.5 × 45 mm dimensions apply to the uncapped cell body. Use that size to check holder seating, and allow extra space above the cell because the overall height with the lid in place is not stated here.
Z Height is not stated for this option. If your instrument depends on a fixed beam-centre height or has tight clearance around the cuvette top, check beam position and top clearance before ordering.
Solvents and cleaning
For a method with a defined optical path tolerance, specify that tolerance and its measurement conditions when selecting the Molded 0.01 option. The final requirement is agreed for the order.
Molded 0.01 is the fabrication option used for applications that may require closer optical path control in custom selection. Chemical suitability still depends on the complete assembly and on the actual liquid, concentration, temperature and contact time used in your method.
This cuvette uses a quartz body and includes a lid, so compatibility should be considered for the complete assembly rather than the cell body alone. The exact chemical limits for this option are not stated here. Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and rinse promptly after use with a suitable cleaning method for your application.
Included with this option
This configuration includes an accompanying closure. Confirm the cell quantity and any separately specified accessories covered by your order.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and fabrication details. Send a dimensioned drawing or labelled sketch, along with your instrument or holder information, critical dimensions, sample conditions and target quantity when you contact us.
Additional information
| Weight | 30 g |
|---|