(C302CE) Quartz Standard Cuvette, 30 mm Path, 10.5 mL
Original price was: $141.00.$127.00Current price is: $127.00.
C302CE is a JGS1 quartz standard cuvette with a 30 mm optical path, Two-Way Light layout and 10.5 mL nominal capacity. Its open-top body is supplied with a PTFE lid and built in Molded 83 fabrication for a straightforward long-path UV/Vis cell.
Description
C302CE is a JGS1 quartz standard cuvette for long-path transmission measurements in a familiar rectangular cell body. It combines a 30 mm optical path, an open-top sample chamber and a supplied PTFE lid, so you can fill directly from above and cover the opening during routine handling. Built in Molded 83 fabrication, this option is suited to methods that need a quartz long-path cell and may involve organic-liquid workflows as well as general laboratory sample handling.
- Path Length
- 30 mm
- Sample Volume (Nominal)
- 10.5 mL
- Opening Configuration
- Open Top (Cell Body)
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Standard Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 30 mm |
| Light Transmission Configuration | Two-Way Light |
| Sample Volume (Nominal) | 10.5 mL |
| Uncapped Cell Dimensions | 12.5 × 32.5 × 45 mm |
| Overall Height without Closure | 45 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Flat Lid |
| Closure Material | PTFE |
| Closure Included | Yes |
| Fabrication Method | Molded 83 |
| Opening Configuration | Open Top (Cell Body) |
Choose this option
Choose C302CE when your method specifically needs a 30 mm path in a manually filled standard cuvette rather than a flow cell or special sealed assembly. The open-top format is practical for pipetting, blank exchange and rinsing, while the 10.5 mL nominal capacity matches the longer path length in a full-size sample chamber. Molded 83 fabrication is also part of the selection here: it is a useful direction for quartz cuvettes used in organic-solvent methods, while the actual suitability still depends on your chemical conditions and which parts of the assembly are contacted.
What makes this option different
- 30 mm optical path: match the measurement method to this transmission distance and align the beam through the sample region.
- Two-Way Light: align the opposing optical faces with the transmission beam and use the same orientation for blank and sample readings.
- 10.5 mL nominal capacity: plan the working fill and beam footprint together so liquid covers the illuminated region; nominal capacity is not a minimum working fill.
- Accompanying closure: cover the opening after preparation and allow room to remove it; no pressure or leak-tight rating is specified.
Using this cell
Fill the cuvette from the top opening and make sure the liquid level fully covers the beam during measurement. The nominal capacity describes the cell volume, not a minimum working volume, so do not assume that a partially filled cell will place liquid correctly in the beam path.
For repeatable work, keep the same orientation for blank and sample measurements. Handle the cell by the non-optical outer surfaces where possible, and check for bubbles or residue before placing it in the instrument.
First-use check
- Inspect the optical faces and rim for scratches, chips or contamination.
- Rinse with a suitable blank or cleaning liquid for your method.
- Test the cell in your holder with a blank to confirm beam coverage through the filled sample region.
- Check that your setup gives enough top clearance for filling and lid placement.
Fit and optical alignment
The recorded uncapped dimensions are 12.5 × 32.5 × 45 mm. Use these as body dimensions for basic holder and clearance checks, and leave additional space above the cell for filling and lid handling.
Z Height is not established for this SKU. If your holder or spectrometer relies on a specific beam-center height, check that requirement directly instead of assuming fit from the outside dimensions alone.
Solvents and cleaning
Molded 83 fabrication is commonly selected for quartz cuvettes used in organic-solvent methods, and this cell is also described for laboratory use involving acids, alkalis and organic liquids. Those source statements do not define concentration, temperature or exposure time, and they do not establish the same resistance for every contacted part of the assembly, so the exact sample and cleaning conditions still matter.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Clean the optical faces gently with non-scratching laboratory tissue or another suitable optical-surface material. For fabrication background, see MQ Cuvette Fabrication Glossary.
Included with this option
This configuration includes an accompanying closure. Confirm the cell quantity and any separately specified accessories covered by your order.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz cuvettes for changes to dimensions, path length, sample volume, openings and other build details. If you need a different fit, send your drawing or labelled sketch together with holder information, critical dimensions, sample conditions and target quantity. You can contact us here and reference C302CE.
Additional information
| Weight | 100 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.