(C012CE) Quartz Standard Cuvette, 1 mm Path, 350 µL
Original price was: $137.00.$124.00Current price is: $124.00.
C012CE is a quartz cuvette with a 1 mm optical path, Two-Way Light layout and 350 µL nominal capacity. Its open-top chamber gives direct access for loading and inspection, with an accompanying closure for covering after preparation.
Description
C012CE is a quartz standard cuvette for short-path measurements that use a 1 mm optical path in a slim open-top body. It combines a Two-Way Light layout with a 350 µL nominal capacity, giving you a compact sample region for direct filling and visual checks before measurement.
- Path Length
- 1 mm
- Sample Volume (Nominal)
- 350 µL
- Opening Configuration
- Open Top (Cell Body)
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Standard Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 1 mm |
| Light Transmission Configuration | Two-Way Light |
| Sample Volume (Nominal) | 350 µL |
| External Dimensions | 12.5 × 3.5 × 45 mm |
| Cell Body Dimensions | 12.5 × 3.5 × 45 mm |
| External Dimensions Scope | Body Only |
| Material | Quartz |
| MQ Grade | Molded 83 |
| Closure Included | Yes |
| Fabrication Method | Molded 83 |
| Opening Configuration | Open Top (Cell Body) |
Choose this option
Choose C012CE when your method needs a 1 mm transmission path and you want an open-top standard cuvette rather than a threaded or flow-through format. The 350 µL nominal capacity keeps the sample chamber small, while the Molded 83 fabrication option is the specific build option for this exact SKU and can be a practical choice when your workflow may involve organic-solvent methods or temperature-controlled laboratory work.
What makes this option different
- 1 mm optical path: match the measurement method to this transmission distance and align the beam through the sample region.
- Two-Way Light: align the opposing optical faces with the transmission beam and use the same orientation for blank and sample readings.
- 350 µL nominal capacity: plan the working fill and beam footprint together so liquid covers the illuminated region; nominal capacity is not a minimum working fill.
- Accompanying closure: cover the opening after preparation and allow room to remove it; no pressure or leak-tight rating is specified.
Using this cell
Fill the cuvette from the open top and make sure the liquid covers the beam region used by your instrument. Keep blank and sample measurements in the same orientation, and remove visible bubbles before taking a reading.
Handle the cell by the non-optical outer surfaces where possible to keep the windows clean. A closure is included, but the body itself remains an open-top design and should not be treated as a pressure-rated or leak-tight assembly.
First-use check
- Confirm that your method specifies a 1 mm optical path.
- Place the empty cell in the holder and check body fit and top access clearance.
- Inspect the optical faces for residue, marks or fingerprints before first use.
- Run a blank in the same orientation planned for the sample.
Fit and optical alignment
The listed 12.5 × 3.5 × 45 mm dimensions apply to the body only. Use them to check holder seating and side clearance, and leave additional top clearance for filling and for the included closure.
Z Height is not stated for this option. If your instrument requires a defined beam-center height, verify that point before ordering rather than relying on the body height alone.
Solvents and cleaning
The supplier describes an optically contacted integrated construction. Consider the Molded 83 option when planning organic-solvent or temperature-controlled methods. Check the actual liquids, temperature and contact time for the complete cell and accompanying closure. Even so, the exact chemical limits for this selected cuvette are not listed here, so your sample liquid and cleaning procedure should be checked against the actual operating conditions.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning materials, and wipe the optical faces gently with suitable non-abrasive lab or optical tissue.
Included with this option
This configuration includes an accompanying closure. Confirm the cell quantity and any separately specified accessories covered by your order.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review custom quartz versions for changes to dimensions, optical path length, sample volume, optical windows, Z Height, closures or fabrication requirements. If you need a different fit, send your drawing or labelled sketch together with holder details, key dimensions, sample conditions and target quantity via Discuss your requirements.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.








Reviews
There are no reviews yet.