(C0.52CE) Quartz Standard Cuvette, 0.5 mm Path, 175 µL
Original price was: $190.00.$171.00Current price is: $171.00.
This JGS1 quartz standard cuvette combines a 0.5 mm optical path with a 175 µL nominal capacity in an open-top, two-way light format. The uncapped body measures 12.5 × 3 × 45 mm, which helps when planning holder clearance around a slim short-path cell.
Description
C0.52CE is a JGS1 quartz standard cuvette for short-path UV/Vis work using a 0.5 mm optical path. Its 175 µL nominal capacity, two-way light layout and open-top body make it useful when you want direct pipette access and a slim uncapped cell format. This supplied version has no closure, so the top remains open during filling and measurement.
- Path Length
- 0.5 mm
- Sample Volume (Nominal)
- 175 µL
- Opening Configuration
- Open Top (Cell Body)
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Standard Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 0.5 mm |
| Light Transmission Configuration | Two-Way Light |
| Sample Volume (Nominal) | 175 µL |
| External Dimensions | 12.5 × 3 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 3 × 45 mm |
| Overall Height without Closure | 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | No Closure |
| Closure Included | No |
| Fabrication Method | Molded 83 |
| Opening Configuration | Open Top (Cell Body) |
Choose this option
Choose C0.52CE when your method already calls for a 0.5 mm path and you want an open-top quartz cell without extra cap clearance above the body. The short path and 175 µL nominal capacity suit small-volume transmission measurements, while the uncapped 12.5 × 3 × 45 mm body gives you a clear geometry to check against the holder and surrounding space.
What makes this option different
- 0.5 mm optical path: match the measurement method to this transmission distance and align the beam through the sample region.
- Two-Way Light: align the opposing optical faces with the transmission beam and use the same orientation for blank and sample readings.
- 175 µL nominal capacity: plan the working fill and beam footprint together so liquid covers the illuminated region; nominal capacity is not a minimum working fill.
- Closure not included: plan the sample-loading procedure around the supplied cell configuration and specify any required cover separately.
Using this cell
Load the sample from the top opening and fill so the beam passes through a fully covered liquid region. The 175 µL nominal capacity describes the cell volume, not a minimum working fill, so your actual usable fill level still depends on your beam position and handling method.
Because no closure is included, this version suits routines where an open sample chamber is acceptable during loading and reading. Handle the cuvette by non-optical outer surfaces and remove visible bubbles before measurement.
First-use check
- Inspect the optical faces and top opening for chips, dust or transit damage.
- Test fit the empty cell in your holder before preparing samples.
- After filling, confirm that the beam passes through a bubble-free liquid region.
Fit and optical alignment
The stated 12.5 × 3 × 45 mm dimensions apply to the uncapped cell body. Use those dimensions to check holder slot size, seating and top clearance before ordering, especially in tightly machined adapters or accessories built around a particular body thickness.
Z Height is not established for this exact SKU, so beam-height compatibility should be checked where your instrument uses a fixed optical center. Two-Way Light refers to the standard opposing transmission direction; it should not be taken as a broader instrument-compatibility claim.
Solvents and cleaning
Molded 83 is commonly selected for methods that may involve organic solvents. For this cell, the source also describes qualitative resistance to acids, alkalis and organic liquids, but it does not define concentration, temperature or exposure time. Match the sample and cleaning routine to your own chemical conditions rather than treating that statement as a universal compatibility list.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the exterior optical faces gently with non-abrasive optical tissue.
Included with this option
No closure is included with this configuration. Confirm the cell quantity and any separately specified accessories covered by your order.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch and identify the dimensions and tolerances that are critical to your application. Prototype batches typically involve 2–4 cells; the final quantity, feasibility, specifications, price and production time are confirmed in the project quotation. Modified designs and prototype batches are quoted separately from the listed SKU. Discuss your requirements.