(C012CA1) Quartz Standard Cuvette, 1 mm Path, 350 µL
Description
C012CA1 is a JGS1 quartz standard cuvette for methods that use a 1 mm optical path in a compact rectangular cell. Its 350 µL nominal capacity suits short-path work with small fills, while the open-top body gives direct access for pipetting and routine loading. A closure is included so the filled cell can be covered during handling.
- Path Length
- 1 mm
- Sample Volume (Nominal)
- 350 µL
- Opening Configuration
- Open Top (Cell Body)
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Standard Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 1 mm |
| Light Transmission Configuration | Two-Way Light |
| Sample Volume (Nominal) | 350 µL |
| Uncapped Cell Dimensions | 12.5 × 3.5 × 45 mm |
| Overall Height without Closure | 45 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Flat Lid |
| Closure Included | Yes |
| Opening Configuration | Open Top (Cell Body) |
Choose this option
Choose C012CA1 when your method is written for a 1 mm transmission path and you want that path in a simple open-top cuvette rather than a flow cell or multi-access design. This format is useful when direct filling matters, and when a modest nominal volume helps you plan sample preparation without moving to a larger chamber.
What makes this option different
- 1 mm optical path: match the measurement method to this transmission distance and align the beam through the sample region.
- Two-Way Light: align the opposing optical faces with the transmission beam and use the same orientation for blank and sample readings.
- 350 µL nominal capacity: plan the working fill and beam footprint together so liquid covers the illuminated region; nominal capacity is not a minimum working fill.
- Accompanying closure: cover the opening after preparation and allow room to remove it; no pressure or leak-tight rating is specified.
Using this cell
Fill the cell from the top and make sure the liquid level covers the beam area used by your instrument. With short-path, small-volume cells, visible bubbles and inconsistent fill level can affect routine use, so it helps to load carefully and keep the same orientation for blank and sample measurements.
The 350 µL figure is a nominal capacity for the cell. It should not be treated as a minimum working volume, and no minimum fill condition is established here.
First-use check
- Inspect the optical faces and top opening for chips, residue or handling marks.
- Test the empty cell in your holder to confirm seating and top clearance.
- Rinse according to your lab practice before first measurement.
- Run a blank in the same orientation and fill style you will use for samples.
Fit and optical alignment
This is a Two-Way Light cuvette intended for straightforward transmission alignment through the main opposing optical faces. It is best suited to holders and methods that accept this standard rectangular cell style and do not depend on side optical access.
Z Height is not established for this SKU. If your holder, beam position or method depends on a specific beam-center height, please verify that point before ordering rather than relying on body shape alone.
Solvents and cleaning
This quartz cuvette is described for contact with acids, alkalis and organic liquids, but the operating conditions are not specified. Check your actual sample, concentration, temperature, contact time and whether the closure will contact the liquid in your process.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Wipe the exterior optical faces gently with non-abrasive optical tissue. For general background, see fabrication methods of cuvettes.
Included with this option
This configuration includes an accompanying closure. Confirm the cell quantity and any separately specified accessories covered by your order.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch and identify the dimensions and tolerances that are critical to your application. Discuss your requirements and quote part number C012CA1.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.