(C012CE1) Quartz Standard Cuvette, 1 mm Path, 350 µL
Description
C012CE1 is a JGS1 quartz standard cuvette for short-path transmission work with a 1 mm optical path. The 350 µL nominal capacity keeps the sample chamber compact, and the open-top body makes filling and rinsing straightforward in routine lab use. A closure is included so the cell can be covered after loading.
- Path Length
- 1 mm
- Sample Volume (Nominal)
- 350 µL
- Opening Configuration
- Open Top (Cell Body)
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Standard Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 1 mm |
| Light Transmission Configuration | Two-Way Light |
| Sample Volume (Nominal) | 350 µL |
| Uncapped Cell Dimensions | 12.5 × 3.5 × 45 mm |
| Overall Height without Closure | 45 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Flat Lid |
| Closure Included | Yes |
| Opening Configuration | Open Top (Cell Body) |
Choose this option
Choose C012CE1 when you need a 1 mm rectangular quartz cuvette with direct top access instead of a larger-volume cell or a side-access optical format. It is a practical option for methods that depend on short path length first, while still using a familiar standard cuvette form for loading and holder setup.
What makes this option different
- 1 mm optical path: match the measurement method to this transmission distance and align the beam through the sample region.
- Two-Way Light: align the opposing optical faces with the transmission beam and use the same orientation for blank and sample readings.
- 350 µL nominal capacity: plan the working fill and beam footprint together so liquid covers the illuminated region; nominal capacity is not a minimum working fill.
- Accompanying closure: cover the opening after preparation and allow room to remove it; no pressure or leak-tight rating is specified.
Using this cell
Load the sample from the top opening and fill to a level that covers the beam area used by your instrument. In a short-path cell, careful filling helps reduce problems from bubbles or uneven liquid level, especially when you are preparing blanks and samples in small quantities.
The nominal capacity is 350 µL. That value describes the cell’s stated capacity and should not be treated as a minimum working volume for your method.
First-use check
- Inspect the optical faces and top opening for chips, dust or handling residue.
- Place the empty cell in your holder to confirm seating and clearance.
- Rinse according to your lab procedure before first use.
- Run a blank in the same orientation you will use for sample measurements.
Fit and optical alignment
This cuvette uses a Two-Way Light arrangement, so it is intended for standard transmission measurements through the main opposing windows. It does not provide a confirmed side optical access configuration, so choose it for setups built around a straightforward transmission path.
Z Height is not established for this SKU. If your instrument holder depends on a specific beam-center height, please check that requirement before ordering rather than assuming fit from the general rectangular form.
Solvents and cleaning
This quartz cuvette is described for contact with acids, alkalis and organic liquids, but no concentration, temperature or exposure limits are stated. The closure material and its sample-contact compatibility are also not established here, so review the full liquid conditions used in your process.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Clean the outer optical faces gently with non-abrasive optical tissue. For general background, see fabrication methods of cuvettes.
Included with this option
This configuration includes an accompanying closure. Confirm the cell quantity and any separately specified accessories covered by your order.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch and identify the dimensions and tolerances that are critical to your application. Discuss your requirements and quote part number C012CE1.