(C022CF1) Quartz Standard Cuvette, 2 mm Path, 700 µL
Original price was: $156.00.$141.00Current price is: $141.00.
C022CF1 is a JGS1 quartz standard cuvette for UV/Vis work with a 2 mm optical path, Two-Way Light geometry and 700 µL nominal capacity. Its open-top body allows direct filling, and a lid is included for covered handling after loading.
Description
C022CF1 is a JGS1 quartz standard cuvette for UV/Vis spectroscopy with a 2 mm optical path and 700 µL nominal capacity. The open-top body lets you fill the sample directly from above, while the included lid covers the opening during routine handling. This version is also specified in the Molded 0.01 fabrication category, which matters when your method or purchasing specification calls for that exact build option.
- Path Length
- 2 mm
- Sample Volume (Nominal)
- 700 µL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Standard Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 2 mm |
| Light Transmission Configuration | Two-Way Light |
| Sample Volume (Nominal) | 700 µL |
| Uncapped Cell Dimensions | 12.5 × 4.5 × 45 mm |
| Overall Height without Closure | 45 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Included | Yes |
| Fabrication Method | Molded 0.01 |
| Opening Configuration | Open Top |
Choose this option
Choose C022CF1 when you need a short 2 mm path in a standard rectangular quartz cuvette rather than a special micro-accessory format. The 700 µL nominal volume suits methods that use a relatively small sample charge but still need direct top access for pipetting, inspection and routine bench handling. It is a practical choice when the optical path, open-top loading style and the specified Molded 0.01 fabrication category all need to stay aligned with your method or project documentation.
What makes this option different
- 2 mm optical path: match the measurement method to this transmission distance and align the beam through the sample region.
- Two-Way Light: align the opposing optical faces with the transmission beam and use the same orientation for blank and sample readings.
- 700 µL nominal capacity: plan the working fill and beam footprint together so liquid covers the illuminated region; nominal capacity is not a minimum working fill.
- Open-top access: load and rinse through the sample opening, leaving room above the body for filling and any accompanying closure.
- Molded 0.01 option: review the required optical-path tolerance and measurement conditions for your order when precision is central to the method.
Using this cell
Fill the cell from the top opening and make sure the liquid level fully covers the beam area during measurement. For repeatable UV/Vis work, keep the same orientation for blank and sample, and check that no bubbles remain in the optical path before placing the cuvette in the instrument.
The lid is useful after filling, but this remains an open-top cuvette rather than a sealed or pressure-rated assembly. Handle the cell by non-optical surfaces where possible to keep the transmission faces clean.
First-use check
- Inspect the optical faces and the top opening for dust, residue or handling marks.
- Test the fit in your holder before preparing important samples.
- After filling, confirm that the beam area is fully covered and free of visible bubbles.
Fit and optical alignment
The uncapped body measures 12.5 × 4.5 × 45 mm. These dimensions are useful for checking holder clearance, top access and whether your setup has enough space above the cuvette for filling and lid placement.
Z Height is not stated for this model. If your instrument has a fixed beam position or limited vertical adjustment, check beam alignment against your own holder or fixture before ordering. The listed 45 mm height applies to the uncapped body, not an assembled overall height with the lid in place.
Solvents and cleaning
Molded 0.01 is the option to consider when your method calls for closely specified optical-path precision. For the 2 mm path on this cell, agree the required tolerance and measurement conditions for the order.
If your work depends on a particular sample chemistry, cleaning liquid or long contact time at the opening and lid area, review the full assembly against your method requirements rather than assuming one universal compatibility rule for every liquid.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Clean the optical faces gently with non-abrasive optical tissue and a suitable cleaning liquid for your process.
Included with this option
This configuration includes an accompanying closure. Confirm the cell quantity and any separately specified accessories covered by your order.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and fabrication. Send a dimensioned drawing or labelled sketch and identify the dimensions and tolerances that are critical to your application, along with holder details, wavelength range, sample conditions and target quantity. Prototype batches typically involve 2–4 cells; final feasibility, specifications, price and production time are confirmed in the quotation. To discuss a custom project, use Discuss your requirements.