(C104TS2) 10 mm JGS1 Quartz Screw-Top Cuvette, 3.5 mL, PTFE Cap
Original price was: $171.00.$154.00Current price is: $154.00.
C104TS2 is a JGS1 quartz screw-top cuvette with a 10 mm optical path, Four-Way Light geometry and 3.5 mL nominal capacity. Its single threaded top opening and included PTFE screw cap suit routine filling and covered handling for UV/Vis and fluorescence work. Sold as 1 cuvette.
Description
C104TS2 is a JGS1 quartz screw-top cuvette for UV/Vis and fluorescence setups that use a 10 mm optical path and need optical access from four sides. It combines a 3.5 mL nominal capacity with a single threaded top opening and a supplied PTFE screw cap, so you can fill directly from above and keep the sample covered during handling or measurement. Sold as 1 cuvette.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 3.5 mL
- Opening Configuration
- Single Threaded Opening
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Screw-Top Cuvette |
| Measurement Mode | UV/Vis Spectroscopy; Fluorescence Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 3.5 mL |
| External Dimensions | 12.5 × 12.5 × 38 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 38 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 54 mm |
| Overall Dimensions with Closure | 12.5 × 12.5 × 58 mm |
| Overall Height without Closure | 54 mm |
| External Dimensions Scope | Body Only |
| Overall Height with Closure | 58 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Screw Cap |
| Closure Material | PTFE |
| Closure Included | Yes |
| Fabrication Method | Molded 83 |
| Opening Configuration | Single Threaded Opening |
Choose this option
Choose C104TS2 when your method uses a standard 10 mm path but also benefits from Four-Way Light geometry rather than a simple two-face transmission layout. This format is useful when you need side optical access for fluorescence arrangements or want a capped rectangular quartz cell for routine liquid work. The single-piece sale unit also suits replacement purchases and single-position setups.
What makes this option different
- 10 mm optical path for methods written around a 10 mm cuvette.
- Four-Way Light geometry for measurement setups that use optical access on multiple sides.
- Single threaded opening with PTFE screw cap for top filling and covered sample handling.
- Sold as 1 cuvette for individual use or replacement.
Structure and dimensions


Using this cell
Fill the cuvette through the threaded top opening and make sure the liquid level covers the beam area used by your instrument. Keep the optical faces clean, and remove visible bubbles from the path before measurement.
The supplied screw cap is useful when you want the sample chamber covered during handling or during a measurement sequence. It should not be treated as a pressure-rated closure.
First-use check
Before first use, inspect the optical faces for dust, fingerprints or residue. Rinse with a solvent appropriate for your method, run a blank at your working wavelength, and confirm that your normal fill level covers the beam in the installed position.
Fit and optical alignment
The body measures 12.5 × 12.5 × 38 mm. Overall height is 54 mm uncapped and 58 mm with the cap fitted, which helps when checking lid clearance or tight vertical space inside the sample compartment.
Z Height is not established for this SKU, so beam-center alignment should be checked in your own holder if your instrument depends on a defined beam height. Four-Way Light describes the optical access category of the cell itself and should not be read as automatic compatibility with every fluorescence instrument.
Solvents and cleaning
Molded 83 is generally selected for quartz cuvette methods involving organic solvents or temperature-controlled work. Review the sample liquid, concentration, temperature and contact time for the complete assembly, including the PTFE cap. Send aggressive or heated operating conditions for a compatibility review before use.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning materials. Wipe the optical faces gently with non-abrasive optical tissue.
Included with this option
One quartz screw-top cuvette with a PTFE screw cap and storage box. The injectable cap shown in the supplier options is a separate accessory, not the supplied standard cap.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch and identify the dimensions and tolerances that are critical to your application. Discuss your requirements and quote part number C104TS2.
Additional information
| Weight | 30 g |
|---|---|
| Dimensions | 1.25 × 1.25 × 4.5 mm |
You must be logged in to post a review.







Reviews
There are no reviews yet.