(C014CR10) Quartz Fluorescence Cuvette, 1 mm Path, 350 µL
Original price was: $237.00.$214.00Current price is: $214.00.
C014CR10 is a JGS3 quartz fluorescence cuvette with a 1 mm optical path, Four-Way Light access and 350 µL nominal capacity. This open-top IR-use version is intended for infrared and fluorescence work in the stated 260–3500 nm range and includes a closure.
Description
C014CR10 is a JGS3 quartz fluorescence cuvette for infrared and fluorescence measurements that use a short 1 mm optical path. Its Four-Way Light layout, open-top chamber and 350 µL nominal capacity make it useful when you need direct filling and optical access from multiple sides in a compact cell format. The stated 260–3500 nm range identifies this IR-use version of the cuvette style.
- Path Length
- 1 mm
- Sample Volume (Nominal)
- 350 µL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Fluorescence Cuvette |
| Measurement Mode | Infrared Spectroscopy; Fluorescence Spectroscopy |
| Path Length | 1 mm |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 260 nm |
| Wavelength Range — Upper Limit | 3500 nm |
| Sample Volume (Nominal) | 350 µL |
| External Dimensions | 12.5 × 3.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 3.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS3 |
| Closure Type | Lid |
| Closure Included | Yes |
| Opening Configuration | Open Top |
Choose this option
Choose C014CR10 when your method is built around a 1 mm path and you want an open-top cell rather than a valve or tubing connection. The JGS3 material and stated 260–3500 nm range make it the infrared-use option in this format, while Four-Way Light access supports fluorescence arrangements that use side optical geometry.
What makes this option different
- 1 mm optical path: match the measurement method to this transmission distance and align the beam through the sample region.
- Four-Way Light: use the available side faces to arrange illumination and collection in a measurement geometry suitable for this cell.
- 350 µL nominal capacity: plan the working fill and beam footprint together so liquid covers the illuminated region; nominal capacity is not a minimum working fill.
- Open-top access: load and rinse through the sample opening, leaving room above the body for filling and any accompanying closure.
- Supplier-described fused integrated construction: keep the body assembled for routine cleaning and rinse through the sample opening, using liquids suitable for the complete quartz assembly.
Using this cell
Fill the cell from the top and keep the same orientation for blank and sample measurements. Before reading, check that the liquid level covers the illuminated region and that no bubbles or droplets sit in the beam area.
For fluorescence work, align the transmitting faces with the excitation and collection directions used by your setup. For infrared work, also check that your holder and method are arranged for this cell geometry and the stated wavelength range.
First-use check
- Inspect the optical faces and top opening for dust, residue or scratches.
- Check the uncapped body fit in your holder before loading sample.
- Run a blank in the same orientation planned for the sample.
Fit and optical alignment
The confirmed external dimensions apply to the uncapped cell body: 12.5 × 3.5 × 45 mm. These dimensions help you check holder seating and side clearance for the bare cell body.
The closure is not included in that dimension set, so allow additional top clearance if your setup is tight above the cell. Z Height is not listed for this SKU, which matters if your instrument depends on a fixed beam-center height rather than a more adjustable holder.
Solvents and cleaning
Rinse the cell with a solvent suitable for your method and wipe the outer optical faces gently with non-abrasive optical tissue. The JGS3 quartz body is specified for this infrared-use cuvette, but chemical limits for the full assembly are not stated here.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. If your sample or cleaning routine involves aggressive chemicals, extended contact time or unusual temperature conditions, please check suitability before use.
Included with this option
This configuration includes an accompanying closure. Confirm the cell quantity and any separately specified accessories covered by your order.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for changes to dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Modified designs are quoted separately from this listed JGS3 cuvette. Discuss your requirements and quote part number C014CR10.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.





Reviews
There are no reviews yet.