(C702CR) Quartz Standard Cuvette, 70 mm Path, 24 mL
Original price was: $128.00.$116.00Current price is: $116.00.
C702CR is a JGS1 quartz Standard Cuvette with a 70 mm optical path, a Two-Way Light layout and 24 mL nominal capacity. Its open-top, no-closure format gives direct access to the sample chamber for filling, decanting and rinsing. The current MQ price unit is 1 piece.
Description
C702CR is a JGS1 quartz Standard Cuvette built for measurements that need a 70 mm optical path in a larger rectangular cell body. Its 24 mL nominal capacity and open-top format make it straightforward to fill, pour out and rinse when your method can work with an uncovered sample surface. The current MQ offer is priced per 1 piece.
- Path Length
- 70 mm
- Sample Volume (Nominal)
- 24 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Standard Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 70 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 24 mL |
| External Dimensions | 12.5 × 72.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 72.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Body Height | 45 mm |
| Base Dimensions | 12.5 × 72.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | No Closure |
| Closure Included | No |
| Opening Configuration | Open Top |
Choose this option
Choose C702CR when you need a long transmission path together with direct top access to the sample chamber. This format suits bench handling where you want to load and empty the cell from above, and where the longer 72.5 mm body can be accommodated in the holder and surrounding space.
What makes this option different
- 70 mm optical path for methods that require a longer beam path through the sample.
- 24 mL nominal capacity in a full-size rectangular cuvette body rather than a short micro-volume format.
- Open top with no closure for direct pipetting, pouring and chamber rinsing, with no lid clearance or cap handling during use.
- Two-Way Light configuration for transmission through two opposite optical faces.
- Uncapped dimensions of 12.5 × 72.5 × 45 mm to check holder length, seating area and space above the cell.
- Fused integrated construction as the supplier’s construction term, supporting a single assembled cell body format without separate cap or plate handling in routine loading and rinsing.
Using this cell
Load the sample from the open top and use a fill level that covers the active beam path during measurement. After the run, the same open access makes decanting and rinsing straightforward, which is useful when you change samples manually between readings.
Because this cell has no closure, it is best suited to procedures that can work with an exposed liquid surface during handling and measurement. Hold the cuvette by the non-optical surfaces, and wipe the outside faces before placing it in the instrument or holder.
First-use check
- Inspect the optical faces and chamber for dust, chips or packing residue.
- Place the cell in the holder and confirm stable seating and enough top clearance for loading.
- Run a blank in the same orientation you plan to use for the sample.
Fit and optical alignment
The optical path runs across two opposite faces in a Two-Way Light arrangement. Check the holder opening, support length and surrounding clearance against the uncapped 12.5 × 72.5 × 45 mm body, especially if your fixture was designed around a shorter standard cell.
Z Height is not listed here, so path length alone does not establish beam-height interchangeability. If your instrument has a fixed beam position, compare the seating and beam alignment requirements with your current holder before ordering.
Solvents and cleaning
Rinse and clean the cell according to the liquids used in your method, taking the open-top handling format into account. The detailed chemical limits for this exact SKU are not established here, so if your procedure uses specific solvents, concentrated chemicals or aggressive cleaning routines, check suitability before routine use.
Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the optical faces gently with suitable non-abrasive optical tissue.
For general cuvette fabrication background, see Fabrication Method of Cuvettes.
Included with this option
Supplied as 1 cuvette. This option is an open-top cell and does not include a lid or closure.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a related quartz cell with different body dimensions, path length, chamber volume or top-access geometry, send your drawing or holder information and identify the dimensions that are critical in your setup.
Discuss your requirements and quote part number C702CR.