(C105CS1) Quartz Tandem Cuvette, 10 mm Path
Original price was: $608.00.$548.00Current price is: $548.00.
C105CS1 is a JGS1 quartz tandem cuvette with a 10 mm optical path, Five-Way Light access and two partitioned open-top chambers in one body. Each chamber is specified at 1.5 mL, so you can handle two separated sample spaces without combining them into one cavity. Supplied as 1 cuvette; a closure is included.
Description
C105CS1 is a JGS1 quartz tandem cuvette built around two partitioned chambers within one cell body. It combines a 10 mm optical path with Five-Way Light access and an open-top layout, so you can fill, inspect and rinse each chamber directly from above. Each chamber is specified at 1.5 mL, while the overall cell capacity is not stated as one combined figure.
- Path Length
- 10 mm
- Cell Type
- Tandem Cuvette
- Opening Configuration
- Open Top with Two Partitioned Chambers
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Tandem Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm |
| Light Transmission Configuration | Five-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Body Height | 45 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Included | Yes |
| Fabrication Method | Molded 83 |
| Opening Configuration | Open Top with Two Partitioned Chambers |
| Chamber Count | 2 |
| Internal Height | 35 mm |
Choose this option
Choose C105CS1 when you need two physically separated sample regions in one cuvette body rather than one shared chamber. This format is useful when your setup benefits from keeping two liquids or two portions apart while maintaining the same general body position in the holder. The open top also helps when your handling routine involves direct pipetting, visual checking or manual rinsing between runs.
What makes this option different
- Two partitioned chambers: the internal space is divided into two separate sample regions, each specified at 1.5 mL rather than one larger combined cavity.
- Open-top access: you can fill and rinse each chamber directly from above without tubing or built-in flow connections.
- Five-Way Light category: this cell offers broader optical access than a simple two-face transmission layout, which can matter when chamber orientation and side access are part of the method setup.
- 10 mm optical path: the cell keeps a defined path length within this tandem format instead of changing to a short-path or oversized chamber design.
- 12.5 × 12.5 mm body footprint: the square external form helps you assess holder clearance while the internal partition keeps the two sample spaces separate.
Using this cell
Fill each chamber from the top and keep the chamber identity consistent through blank, sample and rinse steps. Because the chambers are partitioned, this is a two-space format, not one shared sample well. If your method depends on comparing the two sides of the cell body, keep the orientation repeatable each time you place it in the holder.
Before measurement, check that the optical faces along the intended beam path are clean and free from droplets, residue and bubbles. The stated 1.5 mL value applies to each chamber individually and should not be treated as a single whole-cell nominal volume.
First-use check
- Inspect the cuvette for chips, cracks, residue and shipping damage.
- Rinse both chambers with a compatible liquid before first use.
- Place the cell in the holder and verify that the beam passes through the intended chamber and optical faces.
- Run a blank or background check before measuring samples.
Fit and optical alignment
The external body size is 12.5 × 12.5 mm with a 45 mm height, which helps you check whether the cell can sit in your holder without side interference. Inside the body, the chamber region is shown with a 35 mm internal height, but that figure is not a Z Height value.
Five-Way Light identifies the supported optical-access category for this tandem cell. It indicates broader optical access than a simple transmission cell, but it does not by itself define a specific window position, polishing count or instrument match. If your holder requires a defined beam-center height or a specific access direction, confirm that fit before ordering.
Solvents and cleaning
Molded 83 is commonly selected for methods that may involve organic-solvent handling or temperature-controlled work. In this tandem format, choose cleaning and sample conditions for the complete assembled cell, including the included closure, rather than for quartz alone.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning methods. Clean the optical faces with non-abrasive laboratory or optical tissue, and check compatibility carefully if your method involves aggressive chemicals or extended contact time.
Included with this option
Supplied as 1 cuvette. A closure is included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, chamber layout, optical windows or Z Height, closures and fabrication details. Send a dimensioned drawing or labelled sketch together with your holder or instrument information, critical dimensions, sample conditions and target quantity. Prototype batches typically involve 2–4 cells; feasibility, final specifications, price and production time are confirmed in the project quotation. Discuss your requirements.