C104CS21 is a JGS1 quartz ultra-micro cuvette for fluorescence spectroscopy, combining direct open-top loading, Four-Way Light optical access and a 20 µL nominal capacity in a compact 10 mm path cell. Its 8.5 mm Z Height is the key alignment datum for fixed-height beam setups. Sold as 1 cuvette per price unit.
Description
C104CS21 is a JGS1 quartz Ultra-Micro Cuvette for fluorescence spectroscopy when you need a 10 mm optical path in a very small sample region. The open-top body lets you load and inspect the sample directly, while Four-Way Light access supports beam layouts that use side optical access around the cell. Its 8.5 mm Z Height gives you a defined alignment point to check against your holder and beam position.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 20 µL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Ultra-Micro Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Z Height | 8.5 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 20 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Body Only |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Opening Configuration | Open Top |
Choose this option
Choose C104CS21 when your method needs a compact fluorescence cell with direct top access rather than a closed or connected design. The 20 µL nominal capacity suits low-volume sample preparation, and the 10 mm path keeps a familiar optical path length while the 8.5 mm optical-centre height helps you assess beam placement before ordering.
What makes this option different
- Open-top access allows direct filling, inspection and cleaning from above.
- Four-Way Light configuration provides side optical access around the sample region for fluorescence-style beam geometry.
- 10 mm path length gives a full 10 mm optical path within an ultra-micro cell format.
- 20 µL nominal capacity helps you plan low-volume work without treating that figure as a minimum working fill.
- 8.5 mm Z Height gives a bottom-to-optical-centre datum for alignment checks.
- 12.5 × 12.5 × 45 mm body size helps you review holder clearance and seating space around the cell body.
- Quartz body with supplier-labelled HELLMA technology construction is used here in an assembled open-top cell format rather than a demountable plate-style sample area, so routine handling is centred on top loading, stable seating and careful cleaning of the finished cell.
Using this cell
Load the sample from the top opening and fill to a level that fully covers the illuminated region in your actual measurement position. The stated 20 µL is a nominal capacity, so practical fill depends on your beam position and how the sample sits in the cell during use.
Seat the cuvette consistently for blank and sample measurements, and check the optical region before reading. Avoid bubbles, droplets on the optical faces and dried residue near the beam path.
First-use check
- Inspect the optical faces and top opening for chips, residue or handling marks.
- Place the cell in the holder and confirm stable seating on the base reference.
- Run a blank at your intended fill level to verify that the illuminated region is covered without bubbles.
Fit and optical alignment
The body dimensions are 12.5 × 12.5 × 45 mm for the cell body only. Check holder opening, seating depth and clearance around the upper opening, especially if your setup has close overhead hardware or a fixed support frame.
The specified Z Height is 8.5 mm from the base to the optical centre. Match that datum directly to your instrument or adapter when beam height is fixed, because the nominal volume does not by itself show whether your beam will sit correctly within the filled sample region.
Solvents and cleaning
This is a finished quartz cell for direct top loading and optical measurement. Clean it with methods suitable for quartz and for the complete assembled cell, using gentle rinsing and non-abrasive optical tissue on the optical faces.
Chemical limits for the full assembly are not established here. Do not use hydrofluoric acid on quartz, and avoid hot strong alkalis and abrasive cleaning materials. If your method uses organic solvents, aggressive chemicals, elevated temperature or long contact time, check suitability before use.
Included with this option
1 cuvette per listed price unit. Supplied closure or accessory details are not established for this listing.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review custom JGS1 quartz requirements involving dimensions, path length, sample volume, optical access or Z Height, and closure or interface details. Send a dimensioned drawing or labelled sketch together with holder or instrument information, critical dimensions and your sample conditions.
Discuss your requirements and quote part number C104CS21.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.