(C104CD) Quartz Ultra-Micro Cuvette, 10 mm Path, 50 µL
Original price was: $190.00.$171.00Current price is: $171.00.
C104CD is a JGS1 quartz ultra-micro cuvette with a 10 mm optical path, 50 µL nominal capacity, Four-Way Light configuration and 8.5 mm Z Height. Its open-top body gives direct sample access for compatible fluorescence measurement geometry and holder alignment. Supplied as 1 cuvette.
Description
C104CD is a JGS1 quartz ultra-micro cuvette that combines a 10 mm optical path, 50 µL nominal capacity and Four-Way Light configuration in a compact 12.5 × 12.5 × 45 mm body. Its 8.5 mm Z Height is one of the key selection points when your holder or optical setup needs a lower beam-center position than a full-height standard cell.
The open-top format gives direct access to the sample region for filling, rinsing and visual checking from above. For fluorescence spectroscopy setups with compatible beam geometry, the four-side optical layout can be useful where side optical access is part of the measurement arrangement.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 50 µL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Ultra-Micro Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Z Height | 8.5 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 50 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Body Only |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Opening Configuration | Open Top |
Choose this option
Choose C104CD when you need a 10 mm path in an ultra-micro body and your setup depends on an 8.5 mm optical center. The combination of a small nominal volume, open-top access and Four-Way Light configuration makes this model relevant for fluorescence spectroscopy arrangements that use a compact square cell and need the beam to meet the sample region at that stated height.
What makes this option different
- 8.5 mm Z Height gives a defined base-to-optical-center reference for holder and beam-height matching.
- Four-Way Light configuration supports optical access from four sides in suitable fluorescence measurement geometry.
- Open-top body allows direct filling, rinsing and sample inspection from above.
- 10 mm optical path fits methods written around that path length while staying in an ultra-micro format.
- 50 µL nominal capacity keeps the sample region small without changing to a non-square external body.
- Supplier-labelled HELLMA technology identifies a supplier process designation for this SKU, but the joining method is not specified here, so it is best treated as a construction label rather than a promise of a particular solvent range, tolerance or performance level.
Using this cell
Fill from the open top and make sure the sample level covers the illuminated region used by your instrument. The 50 µL value is the nominal chamber capacity, not a minimum working volume, so the actual fill needed depends on your beam size and optical layout.
Keep the cell orientation consistent between blank, standard and sample measurements so the same faces stay in the same optical positions. This format is intended for upright use with direct access to the sample, not as a sealed or pressure-rated cell.
First-use check
- Inspect the optical faces and top opening before first use.
- Place the cell in your holder and confirm stable seating and beam-height alignment.
- Run a blank at the intended fill level and check that the illuminated region is fully covered without bubbles.
Fit and optical alignment
The cuvette body is 12.5 × 12.5 × 45 mm, which helps you check seating in a square-cell holder and top clearance around the opening. The listed body dimensions apply to the cuvette body itself.
The stated Z Height is 8.5 mm from the base to the optical center, so this value should be matched directly to your instrument or fixture. Four-Way Light describes the optical access category only; it does not by itself establish fit with every fluorescence instrument or holder design.
Solvents and cleaning
This cuvette is made from JGS1 quartz. The exact joining details and assembly-specific chemical limits are not established here, so choose sample liquids and cleaning steps with your actual chemistry in mind, especially for aggressive solvents, extended soaking or elevated-temperature cleaning.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the optical faces gently with non-abrasive optical tissue. For general fabrication background, see this overview.
Included with this option
Supplied as one cuvette. No additional package contents are established here.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for changes involving dimensions, optical path length, sample volume, optical windows, Z Height and related fitting requirements. Send a dimensioned drawing or labelled sketch, your holder or instrument details, sample conditions and target quantity. Discuss your requirements and quote part number C104CD.