(C104CS40) Quartz Micro Cuvette, 10 mm / 4 mm (dual path) Path, 1.4 mL
Original price was: $323.00.$291.00Current price is: $291.00.
C104CS40 is a JGS1 quartz micro cuvette for fluorescence spectroscopy with a 10 mm primary path, 4 mm secondary path and Four-Way Light access. Its 1400 µL nominal capacity supports routine filled-cell work in a compact square body. Sold as 1 cuvette; a closure is included with this option.
Description
C104CS40 is a JGS1 quartz micro cuvette for fluorescence spectroscopy, combining a 10 mm primary path with a 4 mm secondary path in a compact square format. Its Four-Way Light layout gives optical access from four sides, and the 1400 µL nominal capacity provides a practical filled-cell volume for routine fluorescence work.
This cell is suited to methods that need a standard-length primary path but a narrower sample region across the secondary direction. The stated wavelength range is 200–2500 nm. The published 12.5 × 12.5 × 45 mm dimensions apply to the uncapped cell body.
- Path Length
- 10 mm / 4 mm (dual path)
- Sample Volume (Nominal)
- 1.4 mL
- Closure Type
- Lid
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm / 4 mm (dual path) |
| Light Transmission Configuration | Four-Way Light |
| Optical Window Dimensions | 4 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 1.4 mL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Included | Yes |
| Fabrication Method | Molded 83 |
| Detection Channel Width | 4 mm |
Choose this option
Choose C104CS40 when your method uses fluorescence geometry and you want a square micro cuvette with both a 10 mm primary path and a 4 mm secondary path. This layout helps when your setup uses one pair of faces for the main beam and adjacent faces for optical access, while the compact body and 1400 µL nominal capacity keep the cell easy to handle in routine filled measurements.
What makes this option different
- 10 mm primary path with a 4 mm secondary path in one cuvette body.
- Four-Way Light access for optical entry and observation from four sides.
- 1400 µL nominal capacity for routine filled-cell work.
- JGS1 quartz with a stated 200–2500 nm wavelength range.
- Molded 83 fabrication category, based on the supplier’s optical-contact joining description.
- Priced as 1 cuvette for this MQ listing.
Using this cell
Fill the cell so the illuminated sample region is fully covered during measurement, and keep the same orientation for blank and sample runs. In fluorescence work, orientation matters because excitation and collection usually depend on which faces are presented to the instrument.
The 1400 µL figure is the nominal capacity of the cell, not a minimum working volume. Set your actual fill level according to your instrument beam position and the liquid height needed to keep bubbles or meniscus effects out of the optical region.
First-use check
Inspect the cuvette before first use for chips, contamination or visible marks on the optical faces. Rinse it with a liquid suitable for your method, place it in the holder, and run a blank in the same orientation you plan to use for sample measurements.
Fit and optical alignment
The uncapped cell body measures 12.5 × 12.5 × 45 mm. Use those dimensions to check holder clearance, seating depth and top access, and allow extra room for the installed closure because the published size does not include closure height.
Z Height is not established for this SKU. If your fluorimeter or holder depends on a defined beam-center height, please confirm that requirement before ordering rather than relying on the outside body dimensions alone.
Solvents and cleaning
This option falls under MQ’s Molded 83 fabrication category, using the supplier’s optical-contact construction for this SKU. In practice, this category is commonly chosen for methods that may involve organic solvents, but suitability still depends on the complete sample and cleaning conditions for the assembled cell, including the closure.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the optical faces gently with non-abrasive optical tissue.
Included with this option
One C104CS40 quartz micro cuvette. A closure is included with this option.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review custom JGS1 quartz projects for changes to dimensions, path length, sample volume, optical windows, Z Height, closures and fabrication requirements. Send your drawing or labelled sketch, holder or instrument details, sample conditions and target quantity through Discuss your requirements, and refer to part number C104CS40.