(C104CS41) Quartz Micro Cuvette, 10 mm / 4 mm (dual path) Path, 1.4 mL
Original price was: $646.00.$582.00Current price is: $582.00.
C104CS41 is a JGS1 quartz micro cuvette for fluorescence spectroscopy with a 10 mm primary path, 4 mm secondary path and Four-Way Light access. Its 1400 µL nominal capacity supports routine filled-cell work in a compact square body. Priced as 1 cuvette on this MQ listing; a closure is included.
Description
C104CS41 is a JGS1 quartz micro cuvette for fluorescence spectroscopy, combining a 10 mm primary path with a 4 mm secondary path in a compact square format. Its Four-Way Light layout gives optical access from four sides, and the 1400 µL nominal capacity suits routine filled-cell fluorescence work where you want direct side access around the sample region.
This option is useful when your method needs a standard-length primary path but a narrower secondary sample region. The stated wavelength range is 200–2500 nm. The published 12.5 × 12.5 × 45 mm dimensions apply to the uncapped cell body.
- Path Length
- 10 mm / 4 mm (dual path)
- Sample Volume (Nominal)
- 1.4 mL
- Closure Type
- Lid
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Path Length | 10 mm / 4 mm (dual path) |
| Light Transmission Configuration | Four-Way Light |
| Optical Window Dimensions | 4 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 1.4 mL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Included | Yes |
| Fabrication Method | Molded 83 |
| Detection Channel Width | 4 mm |
Choose this option
Choose C104CS41 when your fluorescence setup uses a 10 mm main beam path and benefits from side access around the sample region. The 4 mm secondary path helps define the cross-direction geometry of the sample zone, while the compact square body and 1400 µL nominal capacity make the cell practical for routine loading, blanking and repeated measurement in a consistent orientation.
What makes this option different
- 10 mm primary path with a 4 mm secondary path in one micro cuvette.
- Four-Way Light access for optical use from four sides of the cell.
- 1400 µL nominal capacity for routine filled measurements.
- JGS1 quartz with a stated 200–2500 nm wavelength range.
- Molded 83 fabrication category, based on the supplier’s optical-contact joining description.
- Priced as 1 cuvette on this MQ listing.
- A closure is included.
Using this cell
Fill the cell so the beam passes fully through liquid sample, and keep the optical faces clean for both blank and sample measurements. Use the same orientation each time, especially in fluorescence work where the relationship between the illuminated faces and the instrument geometry affects how the cell is used.
The 1400 µL figure is the nominal capacity of the cuvette, not a minimum working volume. Your actual fill level should be set by the beam position in your instrument and by the liquid height needed to keep bubbles and surface effects away from the optical region.
First-use check
Inspect the cell on arrival for clean, undamaged optical faces and rinse it before first use with a liquid suitable for your method. After placing it in the holder, run a blank in the intended measurement orientation to confirm proper seating and sample coverage across the beam.
Fit and optical alignment
The uncapped body measures 12.5 × 12.5 × 45 mm. Check holder seating, side clearance and top clearance using those body dimensions, and allow additional room for the installed closure because the published size does not include closure height.
Z Height is not established for this SKU. If your holder or fluorimeter depends on a specific beam-center height, please confirm that requirement before ordering rather than relying on outside body dimensions alone.
Solvents and cleaning
This option falls under MQ’s Molded 83 fabrication category, using the supplier’s optical-contact construction for this SKU. In selection terms, this category is commonly chosen for methods that may involve organic solvents, but final suitability depends on the complete sample and cleaning conditions for the assembled cell, including the closure.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe optical faces gently with non-abrasive optical tissue.
Included with this option
One C104CS41 quartz micro cuvette, priced as 1 cuvette on this MQ listing. A closure is included. If you need confirmation of any other included items, please contact us before ordering.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review custom JGS1 quartz projects for changes to dimensions, path length, sample volume, optical windows, Z Height, closures and fabrication requirements. Send your drawing or labelled sketch, holder or instrument details, sample conditions and target quantity through Discuss your requirements, and refer to part number C104CS41.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.







Reviews
There are no reviews yet.