(C502CS5) Quartz High-Capacity Cuvette, 50 mm Path, 125 mL
Original price was: $133.00.$120.00Current price is: $120.00.
C502CS5 is a JGS1 quartz high-capacity cuvette with a 50 mm optical path, Two-Way Light transmission layout and 125 mL nominal capacity. Its large open-top square chamber gives direct access for filling, inspection and rinsing in UV/Vis work that uses a broad static sample region. Sold as 1 cuvette per listed price unit.
Description
C502CS5 is a large JGS1 quartz cuvette for UV/Vis measurements that use a 50 mm optical path and a wide static sample chamber. Its Two-Way Light layout provides a direct transmission path through two opposite optical faces, while the open top gives easy access when you need to fill, inspect or rinse a larger liquid volume. With a 125 mL nominal capacity and a 50 × 50 × 53 mm internal chamber, this format suits methods that need a large square sample region rather than a compact cell.
- Path Length
- 50 mm
- Sample Volume (Nominal)
- 125 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | High-Capacity Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 50 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 125 mL |
| External Dimensions | 54 × 54 × 55 mm |
| Cell Body Dimensions | 54 × 54 × 55 mm |
| External Dimensions Scope | Body Only |
| Internal Dimensions | 50 × 50 × 53 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Open Top |
| Opening Configuration | Open Top |
Choose this option
Choose C502CS5 when your setup is built around a 50 mm transmission path and a large open chamber that you can access directly from above. This format is useful when sample handling matters as much as path length: you can pour or pipette into the square chamber, check the liquid condition from the top, and rinse the cell more easily between runs than with a narrow or closed design.
What makes this option different
- 50 mm optical path suits methods written for a longer transmission path.
- Two-Way Light layout gives a straight optical path through two opposite faces for standard transmission measurements.
- Large square chamber with 50 × 50 × 53 mm internal dimensions provides a broad sample region for larger static fills.
- 125 mL nominal capacity matches applications that need a high-capacity cuvette rather than a compact format.
- Open-top access makes filling, visual checking and rinsing straightforward from above.
- Fused integrated construction is an assembled quartz body rather than a disposable insert, so ordinary handling and rinsing should focus on keeping the optical faces clean and avoiding chips at the top opening and edges.
Using this cell
Fill the cell so the liquid covers the beam region used by your instrument, then remove bubbles from the transmission path before measurement. The square open chamber is practical when you are transferring larger sample volumes by pouring or pipetting and want to check the liquid condition directly from above.
Keep the same cell orientation for blank and sample when your method depends on consistent positioning. Handle the cuvette by non-optical surfaces where possible to reduce fingerprints on the transmission faces.
First-use check
Before first use, inspect the optical faces, top opening and edges for fingerprints, residue or chips. Place the empty cell in the holder first to confirm seating and beam clearance, then run a suitable blank before preparing a full sample volume.
Fit and optical alignment
The body dimensions are 54 × 54 × 55 mm, and these dimensions apply to the body only. This helps when checking holder seating, side clearance and top access around the cell.
The optical layout is Two-Way Light, so plan for beam entry and exit through two opposite faces rather than side access on all four sides. Z Height is not specified for this item, so instrument fit should not be assumed from path length alone; if your holder has a fixed beam height or limited clearance above the cell, check that geometry before ordering.
Solvents and cleaning
This cuvette is made from JGS1 quartz. For general background on cuvette construction, see https://machinedquartz.com/fabrication-method-of-cuvettes/.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Chemical limits for this exact assembly are not established here, so aggressive chemicals, heated cleaning and extended contact conditions should be reviewed before use.
Included with this option
This listing is for one C502CS5 cuvette. A closure or additional accessories are not specified for this option.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review a custom JGS1 quartz version for projects that need different dimensions, path length, capacity or fit details. Send a labelled drawing or sketch, holder or instrument information, sample conditions and required quantity through https://machinedquartz.com/contact/, and reference C502CS5.
Additional information
| Weight | 100 g |
|---|