(C012WS2) Quartz Flow Cell, 1 mm Path, 60 µL
Original price was: $299.00.$270.00Current price is: $270.00.
C012WS2 is a quartz flow cell for UV/Vis work with a 1 mm optical path, Two-Way Light transmission and a 60 µL nominal capacity. Two top M6 fluid connections keep tubing access above the cell body. This listing is for the selected C012WS2 flow cell specification.
Description
C012WS2 is a compact quartz flow cell for UV/Vis spectroscopy with a 1 mm optical path and 60 µL nominal capacity. Its two top M6 fluid connections keep the tubing approach above the cell, while the Two-Way Light layout provides a direct transmission path across the flowing sample.
The body itself is 12.5 × 12.5 × 35 mm, and the stated optical window area is 17.5 × 3.5 mm. This combination is useful when you need a small flow-through sample region in a compact body, but still need room to route connections from above rather than from the sides.
- Path Length
- 1 mm
- Sample Volume (Nominal)
- 60 µL
- Opening Configuration
- Two Top Fluid Connections
Selection Specifications
| Product Kind | Flow Cell |
|---|---|
| Cell Type | Flow Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 1 mm |
| Light Transmission Configuration | Two-Way Light |
| Optical Window Dimensions | 17.5 × 3.5 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 60 µL |
| Cell Body Dimensions | 12.5 × 12.5 × 35 mm |
| Body Height | 35 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Port Count | 2 |
| Port Thread | M6 |
| Fabrication Method | Standard 80 |
| Opening Configuration | Two Top Fluid Connections |
| Fitting Material | PTFE |
Choose this option
Choose C012WS2 when your method is built around a 1 mm UV/Vis flow path and top-entry fluid routing. The compact body helps with holder planning, and the 60 µL nominal capacity gives a defined sample-region volume for the cell itself while keeping the main optical faces free for transmission measurement.
What makes this option different
- 1 mm optical path: suited to UV/Vis methods designed around a short transmission path.
- Two top M6 fluid connections: tubing approaches from above the cell instead of from the sides.
- Two-Way Light layout: measurement is through the main opposing optical faces.
- 17.5 × 3.5 mm window area and 12.5 × 12.5 × 35 mm body: useful reference points for holder clearance and beam placement checks.
Using this cell
Connect your tubing to the two top ports and fill the cell gradually so the sample fully occupies the illuminated region. During setup, it helps to watch the optical window area closely and clear any trapped bubbles before you run a blank or start measurement.
The stated 60 µL is the nominal volume of the cell sample region. It is not the total liquid volume of the complete flow circuit once tubing and other connected parts are added. No pressure rating is stated here, so pressure use should be reviewed for the assembled system.
First-use check
- Inspect the optical faces and port threads for residue or shipping damage.
- Test your tubing connection and confirm that the installed cell clears the holder space.
- Fill slowly with a suitable blank and check that the window area is fully wetted and free of visible bubbles.
Fit and optical alignment
The 12.5 × 12.5 × 35 mm dimensions refer to the cell body itself. They do not include the added space taken by the M6 connections, attached tubing or bend radius above the cell, so leave extra vertical and lateral clearance when planning the installed assembly.
Z Height is not stated for this option. If your holder or instrument depends on a specific beam-center height, check that point before ordering. Two-Way Light describes the optical access pattern, not a guarantee of fit for a particular instrument model.
Solvents and cleaning
This cell uses Standard 80 adhesive-bonded quartz construction. Standard 80 cells are typically chosen for room-temperature water-based samples and buffers. Avoid organic samples and organic cleaning solvents with this adhesive-bonded cell.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Clean the optical faces gently with non-abrasive laboratory tissue or another suitable non-scratching method, and check the full wetted path of your assembled setup for chemical suitability under your actual conditions.
Included with this option
The listed price is for one C012WS2 flow cell.
Additional accessory contents should be confirmed for your order.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We also review custom quartz flow-cell requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch, plus holder details, tubing or fitting requirements, sample chemistry, temperature and target quantity. Discuss your requirements and quote part number C012WS2.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.