(C102SR11) Quartz Micro Cuvette, 10 mm Path, 350 µL
Original price was: $143.00.$129.00Current price is: $129.00.
JGS1 quartz micro cuvette with a 10 mm optical path, Two-Way Light layout and 350 µL nominal capacity for UV/Vis work from 200 to 2500 nm. Its fused integrated construction and narrow 1 mm sample region suit compact micro-volume handling, and it is supplied as 1 cuvette per price unit with closure included.
Description
C102SR11 is a JGS1 quartz micro cuvette with a 10 mm optical path, a Two-Way Light layout and a 350 µL nominal capacity. The compact 12.5 × 12.5 mm footprint keeps it in a familiar cuvette-style format, while the 1 mm sample region and fused integrated construction make it a distinct choice for micro-volume UV/Vis work. This option is sold as 1 cuvette per price unit, with closure included.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 350 µL
- Closure Type
- Stopper
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Optical Window Dimensions | 1 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 350 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Body Height | 45 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Stopper |
| Closure Included | Yes |
| Detection Channel Width | 1 mm |
Choose this option
Choose C102SR11 when you need a standard 10 mm optical path in a smaller quartz cell rather than a larger full-volume cuvette. The JGS1 quartz body is stated for use from 200 to 2500 nm, so it suits UV/Vis methods that need quartz transmission in that range. The fused integrated construction is another practical selection point if you are looking for this specific build style in a compact micro cuvette.
What makes this option different
- 10 mm optical path in a micro format: keeps the standard path length in a smaller nominal volume cell.
- Two-Way Light layout: measurement is through the main opposing optical faces.
- JGS1 quartz, 200–2500 nm: suitable for UV/Vis work across the stated wavelength range.
- 1 mm sample region: important when you check beam coverage and fill height in a small chamber.
Using this cell
Fill the cell so the optical beam passes fully through liquid in the intended sample region, and keep the optical faces free of bubbles, droplets and residue. Use a consistent orientation for blank and sample measurements.
The 350 µL figure is a nominal capacity, not a minimum working volume. If your method uses lower fill levels, verify beam coverage in your own setup before routine measurements.
First-use check
- Inspect the optical faces and edges for chips, dust or shipping residue.
- Test the empty cuvette in your holder before preparing sample.
- Run a suitable blank first and check beam coverage at your intended fill level.
- Keep the same orientation once your measurement setup is established.
Fit and optical alignment
The external body dimensions are 12.5 × 12.5 × 45 mm, with a 12.5 × 12.5 mm base. These dimensions help you check holder seating and general compartment clearance in instruments that accept this style of cuvette body.
Z Height is not established for this SKU, so total body height should not be used as a beam-height substitute. If your instrument or holder has a fixed beam position, check alignment against the actual sample region before ordering for beam-sensitive work.
The Two-Way Light layout means the working optical path is through the main opposing faces rather than side optical access. The stated 1 mm sample region should be treated as a geometry detail for beam and fill planning, not as a general instrument compatibility guarantee.
Solvents and cleaning
This cuvette uses a fused integrated construction, but a customer-facing fabrication grade is not established here. Use cleaning and sample conditions that are suitable for quartz cells and for the complete wetted assembly, especially if your method depends on specific solvent exposure.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. For general fabrication background, see Compare fabrication methods.
Included with this option
1 cuvette per listed price unit. Closure included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
For related custom JGS1 quartz cuvette requirements involving dimensions, path length, sample volume, windows, Z Height, closures or tolerances, please send your drawing or labelled sketch together with holder details, wavelength range and sample conditions. Discuss your requirements and quote part number C102SR11.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.