(C102CS73) Quartz Ultra-Micro Cuvette, 10 mm Path, 50 µL
Original price was: $76.00.$69.00Current price is: $69.00.
C102CS73 is a JGS1 quartz ultra-micro cuvette for UV/Vis work, combining a 10 mm optical path with a 50 µL nominal capacity in a compact covered format. Its Two-Way Light layout suits straight-through measurement through opposing optical faces. Supplied as 1 cuvette per sale unit, with a closure included.
Description
C102CS73 is a JGS1 quartz ultra-micro cuvette for UV/Vis spectroscopy when you need a standard 10 mm optical path but want to work with a 50 µL nominal sample volume. Its Two-Way Light layout keeps the measurement path straightforward through opposing optical faces, and the included closure makes it a covered cell rather than an open-top format. This option is supplied as 1 cuvette per sale unit.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 50 µL
- Closure Type
- Lid
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Ultra-Micro Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 50 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Body Only |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Included | Yes |
Choose this option
Choose C102CS73 when your method is built around a 10 mm absorbance path but your available sample is limited and a 50 µL nominal capacity suits the way you prepare and load the sample. This format is useful for direct UV/Vis transmission measurements where side optical access is not needed. The compact body also helps when you are working with a holder that accepts this ultra-micro cuvette size, provided the beam height is suitable.
What makes this option different
- 10 mm optical path with 50 µL nominal capacity keeps a familiar absorbance path length while moving to a much smaller sample chamber.
- Two-Way Light geometry supports straight-through measurement across the two main optical faces, which suits standard UV/Vis transmission setups.
- Included closure lets you cover the sample during handling and measurement, which is useful when you do not want an open cell format.
- JGS1 quartz for 200–2500 nm use fits UV/Vis methods that need quartz transmission rather than ordinary visible-only glass.
- Supplier-described fused integrated construction is a practical reason to keep cleaning controlled and to check demanding sample or rinse chemistry before routine use, rather than treating the cell as proven for every solvent system.
Using this cell
Fill the cuvette carefully so the illuminated sample region is covered and free of bubbles or films on the optical faces. Because 50 µL is the nominal capacity, it should not be treated as the minimum working volume. For consistent readings, load blank and sample in the same orientation and seat the cell the same way each time.
The closure is useful for covering the cell during normal handling and measurement, but this listing does not state a pressure rating or leak-tight specification. Use it as a covered ultra-micro cuvette, not as a pressure-tested flow cell or reaction vessel.
First-use check
Before first use, inspect the optical faces for dust, fingerprints or chips, then rinse with a method-suitable liquid and run a blank. Confirm that the filled sample covers the beam in your own setup before using valuable material.
Fit and optical alignment
The stated body dimensions are 12.5 × 12.5 × 45 mm, body only. Check holder clearance against the body size and allow for closure space above the cell if your compartment is tight.
Z Height is not established for this SKU. If your instrument has a fixed beam position, confirm that the beam passes through the intended sample region instead of relying on overall body height alone.
Solvents and cleaning
The supplier describes this cuvette as having fused integrated construction. In practical use, that makes it sensible to choose it for routine UV/Vis sample handling with controlled cleaning methods, while checking suitability before using aggressive reagents, mixed organic systems or long solvent contact. For general background, see https://machinedquartz.com/fabrication-method-of-cuvettes/.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the optical faces gently with non-abrasive optical tissue. Exact chemical compatibility limits for this assembled SKU are not established here.
Included with this option
1 cuvette per listed price unit. Closure included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for changes to dimensions, optical path length, sample volume, optical windows or Z Height, closures and fabrication requirements. Send a dimensioned drawing or labelled sketch together with your holder details, beam geometry, sample conditions and target quantity. Prototype batches typically involve 2–4 cells; final specifications, price and production time are confirmed for the project. https://machinedquartz.com/contact/ and quote part number C102CS73.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.




Reviews
There are no reviews yet.