(C102CS74) Quartz Ultra-Micro Cuvette, 10 mm Path, 100 µL
Original price was: $76.00.$69.00Current price is: $69.00.
C102CS74 is a JGS1 quartz ultra-micro cuvette for UV/Vis work with a 10 mm optical path and 100 µL nominal capacity. Its Two-Way Light layout is intended for straight-through measurement through opposing optical faces, and a closure is included. Supplied as 1 cuvette per sale unit.
Description
C102CS74 is a JGS1 quartz ultra-micro cuvette for UV/Vis spectroscopy when you need a full 10 mm optical path in a compact cell with 100 µL nominal capacity. The Two-Way Light layout supports straight-through transmission across opposing optical faces, and the included closure gives you a covered format for routine sample handling. This option is supplied as 1 cuvette per sale unit.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 100 µL
- Closure Type
- Lid
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Ultra-Micro Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 100 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Body Only |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Included | Yes |
Choose this option
Choose C102CS74 when your method is set up around a 10 mm path length but you want a smaller sample chamber than a full-size cuvette. The 100 µL nominal capacity provides more sample space than the smaller 50 µL version while keeping the same compact body style. It suits UV/Vis transmission work where side optical access is not required and where your holder can accept this body format.
What makes this option different
- 10 mm path length with 100 µL nominal capacity suits methods that keep a standard absorbance path but do not need a larger conventional cuvette volume.
- Two-Way Light optical access is intended for straight-through measurement through the main opposing faces, matching typical UV/Vis transmission geometry.
- Compact covered ultra-micro format helps when you want small-volume loading with a closure in place during handling or reading.
- JGS1 quartz over 200–2500 nm makes this option appropriate for UV/Vis work that calls for quartz transmission.
- Supplier-described fused integrated construction means sample chemistry and cleaning method should still be chosen with care, especially when organic solvents or more aggressive wash routines are part of the workflow.
Using this cell
Fill the cuvette so the illuminated sample region is covered during measurement, and load it carefully to avoid bubbles or residue on the optical faces. The stated 100 µL is a nominal capacity, not a minimum working volume. For comparable blank and sample readings, keep the same orientation and seating practice throughout the run.
The included closure helps cover the sample during normal handling, but this listing does not state a pressure rating or leak-tight performance. Use it as a covered measurement cell rather than a sealed process or pressure application.
First-use check
Inspect the optical faces for dust, handling marks or chips before the first run. Rinse with a suitable liquid for your method, seat the cell in the holder, and run a blank to confirm that the beam passes through the intended optical faces in your setup.
Fit and optical alignment
The stated 12.5 × 12.5 × 45 mm dimensions apply to the body only. Check holder seating and top clearance for the closure if your compartment or fixture is tight above the cell position.
Z Height is not established for this SKU. If your instrument depends on a fixed beam height, verify the beam position against the actual sample region before ordering rather than inferring fit from overall body size alone.
Solvents and cleaning
This cuvette is described by the supplier as fused integrated construction. In practical terms, that supports routine UV/Vis use, but it does not remove the need to review your sample and cleaning liquids if you work with mixed solvents, strong reagents or long contact times. General construction background is available here: https://machinedquartz.com/fabrication-method-of-cuvettes/.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the optical faces gently with non-abrasive optical tissue. Exact chemical compatibility limits for this assembled SKU are not established here.
Included with this option
1 cuvette per listed price unit. Closure included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and fabrication details. Send a dimensioned drawing or labelled sketch together with your holder or instrument information, critical dimensions, application wavelength range and sample conditions. Prototype batches typically involve 2–4 cells; final specifications, quantity, price and production time are confirmed in the project quotation. https://machinedquartz.com/contact/ and quote part number C102CS74.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.




Reviews
There are no reviews yet.