(C012WS5) Quartz Flow Cell, 0.1 mm Path, 30 µL
Original price was: $470.00.$423.00Current price is: $423.00.
C012WS5 is a quartz flow cell with a 0.1 mm optical path, 30 µL nominal capacity and two fixed tube connections on the broad faces. This layout is chosen for connected UV/Vis flow work where the illuminated liquid section needs to stay very short and compact. Supplied as 1 flow cell per sale unit.
Description
C012WS5 is a quartz flow cell for UV/Vis work with a 0.1 mm optical path and 30 µL nominal chamber. Its two fixed tube connections place the cell directly into a fluid line, so you can run a connected setup instead of filling an open sample chamber by hand. The integrated-forming construction and compact flat body make it a practical choice when you need a very short flow section and controlled tubing access around the optical position.
- Path Length
- 0.1 mm
- Sample Volume (Nominal)
- 30 µL
- Opening Configuration
- Two Tube Connections
Selection Specifications
| Product Kind | Flow Cell |
|---|---|
| Cell Type | Flow Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 0.1 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 30 µL |
| Cell Body Dimensions | 45 × 12.5 × 2.6 mm |
| Material | Quartz |
| Port Count | 2 |
| Tube Outer Diameter (OD) | 5 mm |
| Tube Inner Diameter (ID) | 3 mm |
| Fabrication Method | Molded 83 |
| Opening Configuration | Two Tube Connections |
Choose this option
Choose C012WS5 when your method needs a 0.1 mm path in a true flow-through format rather than a manually filled cell. The 30 µL nominal chamber keeps the sample region small, and the fixed two-tube layout on the broad faces helps you plan line routing and support around the mounted cell. This option is especially useful when both the optical section and the connected liquid region need to stay compact.
What makes this option different
- 0.1 mm optical path for methods that require a very short liquid path through the beam.
- 30 µL nominal chamber in the cell itself, keeping the illuminated sample region compact.
- Two fixed tube connections on the broad faces so the cell is used as part of a fluid line rather than as an open-fill chamber.
- 5 mm tube outer diameter and 3 mm inner diameter for matching your connected tubing and support parts.
- Integrated forming with the current Molded 83 fabrication designation, a useful selection direction for organic-solvent methods or temperature-involved work when the complete wetted assembly is also suitable.
- 45 × 12.5 × 2.6 mm flat body, with the body dimensions stated separately from the projecting tube sections.
Using this cell
Install the cell as part of your flow path and fill it through the connected tubing. Because this is a fixed two-tube format, access is through the line connections rather than through a top opening or removable cover. Fill and rinse gently so the short optical region wets fully before measurement.
The 30 µL value is the nominal chamber volume of the cell itself. Tubing, fittings and other connected parts add liquid volume outside the cell, so plan priming and sample changeover for the full flow path, not the chamber alone.
No pressure limit is stated for this SKU. If your setup depends on defined operating pressure, confirm the connection method and system conditions before use.
First-use check
Before first use, inspect the optical area and both tube connections for transit residue or damage. Confirm that the cell is supported without twisting the tubes, that your tubing matches the stated connection size, and that the filled optical region is free from visible bubbles.
Fit and optical alignment
The stated 45 × 12.5 × 2.6 mm dimensions apply to the flat cell body only. The projecting tube sections need extra clearance, and the fixed broad-face layout affects how hoses bend away from the mounted cell, so check holder spacing and routing room around both connection ends.
Z Height is not stated for this option. If your holder or instrument requires a defined beam-center height, check that geometry before ordering instead of relying on the body outline alone.
Solvents and cleaning
This SKU is described with an integrated-forming construction and the current Molded 83 fabrication designation. In practical selection terms, that makes it a suitable option to review for organic-solvent methods and temperature-involved applications, provided the complete wetted assembly, including tubing and any fittings, is also appropriate for the chemicals and conditions you plan to use.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Rinse promptly after use, and clean the exterior optical faces gently with non-abrasive optical tissue.
Included with this option
Supplied as 1 quartz flow cell.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch together with holder details, sample conditions and target quantity. Prototype batches typically involve 2–4 cells; final specifications, quantity, price and production time are confirmed in the project quotation. Discuss your requirements and mention part number C012WS5.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.






Reviews