(C022WS4) Quartz Flow Cell, 2 mm Path, 600 µL
Original price was: $394.00.$355.00Current price is: $355.00.
C022WS4 is a quartz flow cell with a 2 mm optical path, a 600 µL nominal cell volume and two fixed tube connections on the broad faces. This layout gives you a connected UV/Vis cell with direct tubing access while keeping the flat body compact for mounting. Supplied as 1 flow cell per sale unit.
Description
C022WS4 is a quartz flow cell for UV/Vis work with a 2 mm optical path and a 600 µL nominal chamber. Its two fixed tube connections sit on the broad faces near the two long ends, so you can connect the liquid line directly while keeping the light path in a flat, compact cell body. This option is useful when you need a connected cell rather than open manual filling, and when holder space around the body matters as much as the chamber specification.
- Path Length
- 2 mm
- Sample Volume (Nominal)
- 600 µL
- Opening Configuration
- Two Tube Connections
Selection Specifications
| Product Kind | Flow Cell |
|---|---|
| Cell Type | Flow Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 2 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 600 µL |
| Cell Body Dimensions | 45 × 12.5 × 4.5 mm |
| Material | Quartz |
| Port Count | 2 |
| Tube Outer Diameter (OD) | 5 mm |
| Tube Inner Diameter (ID) | 3 mm |
| Fabrication Method | Molded 83 |
| Opening Configuration | Two Tube Connections |
Choose this option
Choose C022WS4 when you need a short-path flow cell with direct tube access built into the cell body. The 600 µL nominal chamber gives more sample space than very small short-path designs, while the broad-face port layout keeps the connections accessible from the main faces instead of moving them to a cap or a separate fitting arrangement. If you are planning a compact flow setup, the stated 5 mm tube outer diameter and 3 mm inner diameter give you a clear starting point for matching tubing and line geometry.
What makes this option different
- Two fixed tube connections on the broad faces let you build the fluid line directly around the cell body without an open top or separate closure arrangement.
- 2 mm optical path suits short-path UV/Vis flow measurements in a connected cell format.
- 600 µL nominal cell volume provides a defined chamber that is larger than ultra-micro flow formats without turning the body into a large block.
- 45 × 12.5 × 4.5 mm body dimensions describe the flat cell body only, so you can assess holder seating separately from tube clearance.
- 5 mm OD and 3 mm ID tube dimensions help you match the external connection and understand the tube bore without mixing those two functions.
- Integrated forming, identified here under Molded 83, gives this SKU a built-in connected structure rather than a body that depends on a separate cap-style access point.
Using this cell
Connect your tubing to the two fixed ports and fill the cell gradually so the sample wets the optical region evenly. Before measurement, check the light path area for bubbles, retained droplets or residue, especially after changing samples or reconnecting the line.
The 600 µL figure is the nominal volume of the cell chamber itself. It does not describe the liquid volume in the rest of your tubing assembly, and it is not a minimum working fill value.
First-use check
Inspect the cell body and both tube connections for damage, chips or contamination before the first run. Confirm that your tubing suits the stated connection dimensions, then run a suitable blank through the cell and verify that the optical region fills cleanly without visible bubbles.
Fit and optical alignment
The stated 45 × 12.5 × 4.5 mm dimensions apply to the flat body only. The tube sections project beyond that body, so leave space for tubing approach, bend radius and access to both ports when you check a holder or mounting position.
Z Height is not stated for this option. If your instrument or holder depends on a defined beam-center height, check that requirement before ordering rather than relying on the body size alone.
Solvents and cleaning
This SKU is identified as integrated forming and grouped here under Molded 83. In practical selection terms, that makes it a relevant option for methods where connected flow handling and organic-solvent use may matter, but the actual sample and cleaning choice still depends on the complete wetted assembly and the real exposure conditions.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Clean the optical faces gently with a suitable non-abrasive method for quartz components, and review tubing and fitting materials separately because they are outside the quartz body itself.
Included with this option
Supplied as 1 quartz flow cell.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review custom JGS1 quartz projects involving dimensions, optical path length, sample volume, windows or Z Height, connections, fabrication and tolerance requirements. Send a dimensioned drawing or labelled sketch, together with holder details, tubing layout, sample conditions and the quantity needed. Discuss your requirements and reference C022WS4.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.






Reviews