(C102CS80) Quartz Micro Cuvette, 10 mm Path, 350 µL
Original price was: $29.00.$27.00Current price is: $27.00.
C102CS80 is a black-wall JGS1 quartz micro cuvette for UV/Vis spectroscopy, with a 10 mm optical path, 350 µL nominal capacity and a 1 mm sample-region width. Its Two-Way Light layout keeps the optical path on the main measurement faces, and this sale unit is 1 cuvette with a lid included.
Description
C102CS80 is a black-wall JGS1 quartz micro cuvette for UV/Vis spectroscopy when you need a standard 10 mm path in a compact format. This version combines a 350 µL nominal capacity with a 1 mm sample-region width, making it useful when your method needs a narrow filled measurement zone rather than a broader micro cell. The listed sale unit is 1 cuvette, and a lid is included.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 350 µL
- Closure Type
- Lid
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Optical Window Dimensions | 1 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 350 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Included | Yes |
| Fabrication Method | Standard 80 |
| Detection Channel Width | 1 mm |
Choose this option
Choose C102CS80 when your method is built around a 10 mm absorbance path but you want that path in a small-volume cell with a narrow sample region. The 1 mm channel width and 350 µL nominal capacity make this option relevant where beam placement and limited sample space matter, while the black-wall, Two-Way Light format keeps measurement on the main optical axis for UV/Vis work.
What makes this option different
- 10 mm optical path for methods set up around the standard absorbance length.
- 350 µL nominal capacity in a micro cuvette body.
- 1 mm sample-region width for a narrow illuminated sample zone.
- Black-wall, Two-Way Light layout with transmission through the main optical faces only.
- Sale unit: 1 cuvette with lid included.
Using this cell
Fill the cell so the illuminated region is fully covered during measurement, and keep bubbles out of the beam area. The 350 µL figure is the nominal capacity, not a minimum working volume, so the practical fill level depends on your beam position and how your method is set up.
Use a consistent orientation for blank and sample measurements. Before placing the cell in the holder, keep the optical faces free of fingerprints, droplets and dried residue across the light path.
First-use check
Inspect the optical faces on arrival, rinse with a cleaning liquid that suits your method, and test-fit the empty cell in your holder. A blank run is a practical first check for seating, beam coverage and clean optical surfaces before you add sample.
Fit and optical alignment
The uncapped cell dimensions are 12.5 × 12.5 × 45 mm. These dimensions describe the bare cell body, so if you plan to keep the supplied lid in place during handling or measurement, check the top clearance in your holder separately.
Z Height is not listed for this option. If your instrument or accessory requires a defined beam-center height, verify that point before ordering rather than assuming compatibility from the outside dimensions alone.
Solvents and cleaning
This cuvette uses Standard 80 adhesive-bonded quartz construction. It is suited to routine water-based samples and buffers at room temperature. Avoid organic sample solvents and organic cleaning agents with this construction.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning materials, and wipe the optical faces gently with non-abrasive optical tissue or other suitable optical-surface wipes.
Included with this option
One micro cuvette with lid.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz cuvette projects for changes to dimensions, path length, sample volume, optical windows, Z Height, closure details and fabrication requirements. Send a labelled drawing or sketch, your holder or instrument details, sample conditions and target quantity through the contact page, and refer to part number C102CS80.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.