(C102CS89) Quartz Micro Cuvette, 10 mm Path, 1.75 mL, Pack of 2
Original price was: $57.00.$52.00Current price is: $52.00.
C102CS89 is a JGS1 quartz micro cuvette for UV/Vis spectroscopy with a 10 mm optical path, a 1.75 mL nominal capacity and a 5 mm sample-region width. Its black-wall, Two-Way Light layout suits straight-through measurement through the two optical faces. Sold per price unit as a pack of 2 cuvettes, with lids included.
Description
C102CS89 is a black-wall JGS1 quartz micro cuvette for UV/Vis work with a 10 mm optical path and 1.75 mL nominal capacity. The 5 mm sample-region width and Two-Way Light layout suit direct transmission measurement through the two optical faces in a compact cuvette format. This listing is sold per price unit as a pack of 2 cuvettes, with lids included.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 1.75 mL
- Closure Type
- Lid
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | Pack of 2 |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Optical Window Dimensions | 5 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 1.75 mL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Included | Yes |
| Fabrication Method | Standard 80 |
| Detection Channel Width | 5 mm |
Choose this option
Choose this option when your method uses a 10 mm path and you want this black-wall micro cuvette specification supplied as two cuvettes per price unit. The 1.75 mL nominal capacity gives more filling volume than smaller variants in the same slit-style family, while the 5 mm sample region suits methods that do not need the tightest slit width. The black-wall body keeps the optical direction limited to the two measuring faces for straight-through UV/Vis use.
What makes this option different
- Pack of 2 cuvettes per listed price unit in the same stated specification.
- 10 mm optical path for direct UV/Vis transmission measurements.
- 1.75 mL nominal capacity with a 5 mm sample-region width in the selected slit-style design.
- Black-wall, Two-Way Light construction with JGS1 quartz and lids included.
Using this cell
Fill each cuvette so the illuminated sample region is fully covered during measurement. Keep bubbles and residue away from the optical faces, and use the same seating direction for blank and sample work so the beam crosses the same two optical faces each time.
The 1.75 mL value is the nominal capacity of each cell, not a minimum working volume. Your actual fill level should be based on beam position and the way you handle the cuvette in your instrument.
First-use check
Inspect both cuvettes before first use and look for residue, dried marks or edge damage on the optical faces. Rinse with a suitable liquid for your method, seat each cuvette in the holder, and confirm that the beam passes through the intended optical faces with the sample region fully covered.
Fit and optical alignment
Each uncapped cell body measures 12.5 × 12.5 × 45 mm. Check holder and compartment clearance around the installed lids, because the stated dimensions apply to the uncapped bodies rather than the assembled height with lids fitted.
Z Height is not established for this option. If your holder or instrument depends on a specific beam height, check that geometry directly instead of assuming fit from the 10 mm path length alone. The 5 mm sample-region width should also be considered if your beam footprint is relatively large for this micro cuvette style.
Solvents and cleaning
This cuvette uses Standard 80 adhesive-bonded quartz construction. It is generally suited to routine water-based samples and buffers at room temperature. Avoid organic sample solvents and organic cleaning agents with this construction; if your method depends on organic solvents, ask about a more suitable alternative before ordering.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning methods, and wipe the exterior optical faces gently with non-abrasive optical tissue.
Included with this option
Supplied as a pack of 2 cuvettes with lids and box.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz cuvettes for changes to dimensions, optical path length, sample volume, optical windows, Z Height, closures and fabrication. Send a dimensioned drawing or labelled sketch, together with holder details, sample conditions and target quantity. Discuss your requirements and quote part number C102CS89.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.







Reviews
There are no reviews yet.