(C024TS7) Quartz Micro Cuvette, 2 mm Path, 700 µL
Original price was: $285.00.$257.00Current price is: $257.00.
JGS1 quartz micro cuvette for UV/Vis spectroscopy with a 2 mm optical path, Four-Way Light layout and 700 µL nominal capacity. This covered version gives optical access on all four vertical faces and is supplied as 1 cuvette with closure included.
Description
C024TS7 is a JGS1 quartz micro cuvette for UV/Vis work where you need a 2 mm optical path together with optical access on all four vertical faces. Its Four-Way Light layout is the main distinction from a standard two-face transmission cell, while the covered top format keeps the sample in a closed micro cuvette during routine handling. This listing is priced as 1 cuvette with closure included.
- Path Length
- 2 mm
- Sample Volume (Nominal)
- 700 µL
- Closure Type
- Screw Cap
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 2 mm |
| Light Transmission Configuration | Four-Way Light |
| Sample Volume (Nominal) | 700 µL |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Screw Cap |
| Closure Included | Yes |
| Fabrication Method | Molded 83 |
Choose this option
Choose this option when your setup benefits from four-side optical access rather than only a straight-through two-face path. That can be useful when the cell orientation, observation direction or fixture arrangement needs side access around the sample region while still keeping the selected 2 mm path and a compact 700 µL nominal capacity.
What makes this option different
- 2 mm optical path for short-path UV/Vis measurement methods.
- Four-Way Light configuration with optical access on all four vertical faces.
- 700 µL nominal capacity in a micro cuvette format.
- Sold as 1 cuvette, with closure included for the listed MQ sale unit.
Using this cell
Fill the cell from the top and close it during normal handling and measurement as appropriate for your method. For repeatable results, keep the same orientation for blank and sample measurements and keep all optical faces clean and free from droplets or residue.
The 700 µL figure is the nominal capacity of the cell, not a minimum working volume. If your method uses a low fill or depends on a defined beam position, check that the liquid fully covers the illuminated region in the orientation you will actually use.
First-use check
Inspect the optical faces and closure before first use, rinse with a method-compatible liquid and run a blank at the intended wavelength. Check that the sample level covers the beam path without bubbles in the actual measurement position.
Fit and optical alignment
The Four-Way Light layout provides optical access from each vertical side of the cell body, which can matter when your holder, detector position or viewing direction needs more than a simple two-face transmission path. It does not by itself establish compatibility with any particular instrument or holder geometry.
External dimensions and Z Height are not listed for this SKU. If your instrument has a fixed beam height, a tight micro-cell holder or limited clearance around the top of the cuvette, confirm those requirements before ordering.
Solvents and cleaning
This cuvette is listed in Molded 83, a construction category often selected for organic-solvent methods and temperature-controlled applications. Choose cleaning and sample conditions for the full assembled cell, including the closure, and review suitability first if your process involves aggressive chemicals or extended exposure.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Clean promptly after use and wipe the outer optical faces gently with non-abrasive optical tissue.
Included with this option
Supplied as one quartz micro cuvette. A closure is included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different path length, volume, optical layout, closure style or holder fit, we can review a custom JGS1 quartz version. Please send a drawing or labelled sketch, along with the critical dimensions, instrument details, sample conditions and required quantity, through this contact page and refer to C024TS7.
Additional information
| Weight | 30 g |
|---|---|
| Dimensions | 1.25 × 0.45 × 4.5 mm |