(C024TS8) Quartz Micro Cuvette, 2 mm Path, 700 µL, Pack of 2
Original price was: $567.00.$511.00Current price is: $511.00.
JGS1 quartz micro cuvette for UV/Vis spectroscopy with a 2 mm optical path, Four-Way Light layout and 700 µL nominal capacity. This covered version provides optical access on all four vertical faces and is supplied as a pack of 2, with closures included.
Description
C024TS8 is a JGS1 quartz micro cuvette for UV/Vis methods that use a 2 mm optical path and benefit from optical access on all four vertical faces. The Four-Way Light layout is the key structural distinction, and the covered top format supports routine handling in a closed micro cuvette. This MQ offer is supplied as a pack of 2 cuvettes with closures included.
- Path Length
- 2 mm
- Sample Volume (Nominal)
- 700 µL
- Closure Type
- Screw Cap
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | Pack of 2 |
| Path Length | 2 mm |
| Light Transmission Configuration | Four-Way Light |
| Sample Volume (Nominal) | 700 µL |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Screw Cap |
| Closure Included | Yes |
Choose this option
Choose this option when you want the 2 mm path and four-side optical access of this design, but prefer to buy two matching cuvettes in one listed sale unit. That can suit blank-and-sample work, parallel preparation or keeping a spare cell ready while staying with the same optical layout and nominal 700 µL capacity.
What makes this option different
- 2 mm optical path for short-path UV/Vis methods.
- Four-Way Light configuration with optical access on all four vertical faces.
- 700 µL nominal capacity in a micro cuvette format.
- MQ sale unit is a pack of 2 cuvettes, with closures included.
Using this cell
Fill from the top opening and close the cuvette during normal handling and measurement as required by your procedure. Keep the same orientation from blank to sample, and keep the outer optical faces clean and dry so the beam passes through the liquid sample rather than surface residue.
The stated 700 µL is the nominal capacity of each cuvette. It should not be treated as a guaranteed minimum working volume, so low-fill methods should be checked in the actual holder with attention to beam position and liquid coverage.
First-use check
Inspect both cuvettes and their closures before first use. Rinse with a method-compatible liquid, run a blank in the same orientation planned for measurement, and confirm that the sample level fully covers the illuminated region without bubbles.
Fit and optical alignment
The Four-Way Light layout gives optical access from each vertical face, which can help when your viewing direction or fixture arrangement needs side access beyond a simple two-face transmission path. It does not on its own guarantee fit with a specific spectrometer, fluorimeter or holder.
External dimensions and Z Height are not listed here as customer specifications. If your instrument uses a fixed beam-center height, a tight micro-cell adapter or limited upper clearance around the covered top, confirm those points before ordering.
Solvents and cleaning
Quartz is widely used for UV/Vis work, but the exact chemical limits for this assembled covered configuration are not specified here. Select sample and cleaning conditions for the full cell assembly, and review suitability first if your process involves aggressive solvents, elevated temperature or long contact time.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. After use, rinse promptly and wipe the outer optical faces gently with non-abrasive optical tissue. For general construction guidance, see this fabrication overview.
Included with this option
Supplied as a pack of 2 quartz micro cuvettes with closures included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different path length, sample volume, optical layout, closure style or holder fit, we can review a custom JGS1 quartz version. Please send a drawing or labelled sketch, plus the critical dimensions, instrument details, sample conditions and required quantity, through this contact page and refer to C024TS8.
Additional information
| Weight | 30 g |
|---|---|
| Dimensions | 1.25 × 0.45 × 4.5 mm |
You must be logged in to post a review.







Reviews
There are no reviews yet.