(C104TE15) Quartz Screw-Top Cuvette, 10 mm Path, 3.5 mL, Pack of 2
Original price was: $342.00.$308.00Current price is: $308.00.
Quartz screw-top cuvette for UV/Vis spectroscopy with a 10 mm optical path, Four-Way Light geometry and 3.5 mL nominal capacity. The capped format gives a covered sample chamber in a 12.5 × 12.5 mm square body, with the familiar 10 mm path for routine methods. Supplied as a pack of 2, with caps included.
Description
C104TE15 is a quartz screw-top cuvette for UV/Vis spectroscopy with a 10 mm optical path, Four-Way Light geometry and a 3.5 mL nominal capacity. It gives you a covered screw-cap format instead of an open-top cell, while keeping a square 12.5 × 12.5 mm body that is easy to review against common holder layouts.
This option is useful when you want the standard 10 mm path in a closed sample cell and need optical access on all four sides. It is supplied as a pack of 2, with caps included.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 3.5 mL
- Closure Type
- Screw Cap
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Screw-Top Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | Pack of 2 |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Sample Volume (Nominal) | 3.5 mL |
| Cell Body Dimensions | 12.5 × 12.5 × 35 mm |
| Overall Height without Closure | 55 mm |
| Body Height | 35 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Closure Type | Screw Cap |
| Closure Included | Yes |
| Fabrication Method | Molded 83 |
Choose this option
Choose C104TE15 when your method uses a 10 mm UV/Vis path and you prefer a screw-cap cell for covered handling between filling, blanking and measurement. The 3.5 mL nominal capacity suits full-size liquid measurements, and the Four-Way Light layout can help in setups that use more than one viewing direction through the cell body.
What makes this option different
- 10 mm optical path for UV/Vis methods built around the standard 1 cm path.
- Screw-cap closure for a covered sample chamber; caps are included.
- Four-Way Light geometry with optical access from all four sides of the cell body.
- Sold as a pack of 2 for the listed MQ sale unit.
Using this cell
Fill the cuvette so the liquid level fully covers the beam path used in your instrument, then apply the cap if your procedure calls for a covered cell during handling or measurement. Remove visible bubbles from the optical region and keep the same orientation for blank and sample runs when consistent positioning matters.
The 3.5 mL figure is the nominal capacity of the cuvette, not a minimum working volume. Handle the cell by the non-optical surfaces where possible to keep the light path clean.
First-use check
- Inspect the optical faces and threaded opening for dust, residue or handling marks.
- Rinse with a liquid suitable for your method and the full assembled cell.
- Run a blank in the same orientation planned for sample measurement.
- Confirm that the filled sample covers the beam area in your instrument.
Fit and optical alignment
The cuvette body has a 12.5 × 12.5 mm base and a 35 mm optical body height. These dimensions are the useful starting point when checking holder fit and support at the measurement section.
The uncapped height is 55 mm from the base to the top of the neck. Z Height is not established for this SKU, so if your instrument or holder depends on a defined bottom-to-beam-center position, that requirement should be checked before ordering.
Solvents and cleaning
This cuvette uses Molded 83 fabrication. This fabrication type is commonly selected for quartz cells used in methods that may involve organic solvents or temperature-related work, but the right choice still depends on your actual sample, cleaning liquid and the complete assembled cell.
Chemical limits for this selected assembly are not established here by concentration, temperature or contact time. Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the optical faces gently with non-abrasive optical tissue.
Included with this option
One sales pack contains 2 quartz screw-top cuvettes. Screw caps are included. The exact package contents beyond the cuvettes and caps are not specified here.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and fabrication details. Send a dimensioned drawing or labelled sketch together with holder or instrument information, critical dimensions, sample conditions and target quantity. Discuss your requirements and quote part number C104TE15.
Additional information
| Weight | 30 g |
|---|---|
| Dimensions | 1.25 × 1.25 × 5.5 mm |
You must be logged in to post a review.







Reviews
There are no reviews yet.