(C302CE4) Quartz Rectangular Sample Cell, 30 mm Path
Original price was: $137.00.$124.00Current price is: $124.00.
C302CE4 is an open-top JGS1 quartz rectangular sample cell for UV/Vis transmission work with a 30 mm optical path. Its broad 30 × 30 mm internal section gives direct top access for filling, rinsing and visual checking, while the Two-Way Light layout supports a straight beam path through opposite faces. Sold as 1 cell.
Description
C302CE4 is a JGS1 quartz rectangular sample cell for UV/Vis spectroscopy with a 30 mm optical path and an open-top chamber. The wide 30 × 30 mm internal section gives direct access from above for filling, rinsing and visual inspection, while the Two-Way Light layout suits straightforward transmission measurements through opposite faces.
This option is useful when you need a short, wide sample cell body rather than a tall narrow cuvette shape. Its 34 × 34 × 35 mm body-only format also helps when holder space and top clearance matter as much as the stated path length.
- Path Length
- 30 mm
- Cell Type
- Rectangular Sample Cell
- Opening Configuration
- Open Top (Cell Body)
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Rectangular Sample Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 30 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| External Dimensions | 34 × 34 × 35 mm |
| Cell Body Dimensions | 34 × 34 × 35 mm |
| External Dimensions Scope | Body Only |
| Body Height | 35 mm |
| Internal Dimensions | 30 × 30 × 33 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Open Top |
| Opening Configuration | Open Top (Cell Body) |
| Wall Thickness | 2 mm |
Choose this option
Choose C302CE4 when your method is built around a 30 mm transmission path and you want open access to a broad rectangular sample region. The chamber shape is practical for top filling, pipette access and rinsing between samples, and the quartz body supports UV/Vis use across the listed 200–2500 nm range.
What makes this option different
- Open-top chamber gives direct access to the sample region from above, which is useful for filling, decanting, rinsing and checking the liquid surface before measurement.
- 30 mm optical path suits methods written for this stated transmission length rather than a shorter standard path.
- Two-Way Light layout is arranged for transmission through two opposite faces, making this a straightforward choice when you need a direct beam path across the sample.
- 30 × 30 × 33 mm internal sample region provides a broad rectangular chamber where chamber width and access can matter alongside the optical path.
- 34 × 34 × 35 mm body-only size keeps the outer form compact, but fit should still be checked against your holder and the space needed above the opening.
- Fused integrated construction means this is selected as a fixed open-top cell body rather than a demountable plate assembly, so routine use centers on filling, emptying and gentle rinsing through the top opening.
- 2 mm wall thickness is listed for this option.
Using this cell
Fill the cell from the top and make sure the liquid fully covers the beam region during measurement. Before reading, remove visible bubbles and droplets from the sample area and keep the same orientation for blank and sample runs.
The open chamber makes routine pipetting and rinse-out straightforward. Handle the cell by the non-optical surfaces where possible so the transmission faces stay clean.
First-use check
- Inspect the optical faces and chamber opening for dust, chips or residue.
- Place the empty cell in your holder and confirm that it seats securely.
- Rinse with a suitable liquid for your method before first measurement.
- After filling, check that the beam passes through a bubble-free liquid region.
Fit and optical alignment
The listed 34 × 34 × 35 mm dimensions describe the cell body only. Check holder seating, side clearance and the space above the opening if your instrument or fixture limits top access for filling, emptying or cleaning.
Z Height is not specified for this item, so beam-center fit should not be assumed from body height alone. The nominal volume is also not settled here, so selection is best based on the confirmed path length, sample-region dimensions and body geometry.
Solvents and cleaning
This cell is quartz, but the exact chemical limits for this SKU are not established here. If your process involves aggressive chemicals, heated cleaning or long soaking steps, check suitability for the full use and cleaning routine before regular use.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Clean the optical faces gently with non-abrasive optical tissue. For fabrication background and general selection guidance, see MQ Cuvette Fabrication Glossary.
Included with this option
Supplied as 1 rectangular sample cell. A closure or other accessories are not specified for this item.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz versions for changes involving dimensions, optical path length, optical windows, Z Height, closures, chamber layout and related tolerances. Send a dimensioned drawing or labelled sketch together with your holder details, beam position, sample conditions and required quantity. To discuss a custom version, use this contact page and quote part number C302CE4.