(C1002CA1) Glass Standard Cuvette, 100 mm Path, 35 mL
Original price was: $57.00.$52.00Current price is: $52.00.
C1002CA1 is a glass cuvette for methods that require a 100 mm optical path, with 35 mL nominal capacity. Its lid covers the sample opening after loading; the extended rectangular body needs holder clearance and room to lift the lid. The listed price is for one cuvette.
Description
C1002CA1 is a glass standard cuvette for visible-light measurements from 350 to 2000 nm. It combines a 100 mm optical path with a 35 mL nominal capacity and a lid, giving you a long rectangular sample chamber when your method needs an extended path length rather than a compact cell. Sold as 1 cuvette per MQ sale.
- Path Length
- 100 mm
- Sample Volume (Nominal)
- 35 mL
- Closure Type
- Lid
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Standard Cuvette |
| Measurement Mode | Absorbance Spectroscopy |
| Path Length | 100 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 350 nm |
| Wavelength Range — Upper Limit | 2000 nm |
| Sample Volume (Nominal) | 35 mL |
| External Dimensions | 12.5 × 102.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 102.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Glass |
| Closure Type | Lid |
| Closure Included | Yes |
Choose this option
Choose this cell when your method is written around a 100 mm optical path and you have enough sample to fill a full-size long rectangular chamber. The long path and 35 mL nominal capacity go together in practical use: this is not a small-volume cell, so plan for a larger fill and make sure the liquid level fully covers the beam area used by your instrument. The lid covers the opening during handling, but the published body dimensions apply to the uncapped cell.
What makes this option different
- 100 mm optical path for long-path absorbance setups that use a much longer light path than common short cells.
- 35 mL nominal capacity in a long rectangular chamber, so this option is suited to fuller sample fills rather than micro-volume work.
- Visible-light range of 350–2000 nm, so it is intended for visible and near-infrared use, not UV work.
- Lid closure gives top access for filling and cleaning, then covers the opening for routine handling.
- Glass body with fused integrated construction as stated for this exact item, with cleaning and chemical use needing to suit the complete assembled cell.
Using this cell
Fill from the top opening and place the lid after loading the sample. Because this is a long-path cell with a full-size chamber, the sample should cover the beam region used by your instrument before measurement. Remove visible bubbles and keep the same orientation between blank and sample if your method depends on repeatable positioning.
Handle the cell by the non-optical surfaces where possible, and avoid touching the clear faces. The 35 mL figure is the nominal cell capacity, not a minimum working volume.
First-use check
Inspect the optical faces for dust, residue or handling marks before the first run. Rinse the cell as appropriate for your method, confirm that it sits securely in the holder, and verify that the filled sample level covers the optical path used in your setup.
Fit and optical alignment
The recorded body dimensions are 12.5 × 102.5 × 45 mm for the uncapped cell. Check holder depth, side clearance and top clearance if your compartment is arranged for shorter bodies or for accessories with limited vertical space.
Z Height is not established for this item. If your instrument uses a fixed beam height or a holder with limited adjustment, check the actual beam position against the sample region before ordering or use.
Solvents and cleaning
The supplier describes this item as acid/alkali-resistant and as having fused integrated construction. Specific chemical limits for this SKU are not established here, so avoid treating that wording as a universal compatibility claim for all chemicals, concentrations or cleaning routines.
Use cleaning methods appropriate to the complete assembled cell, and avoid abrasive cleaning that can mark optical surfaces. If your work involves unusual chemicals, long contact times or demanding cleaning steps, review those conditions before ordering. For background on MQ cuvette construction categories, see the fabrication overview.
Included with this option
Price is for 1 cuvette per MQ sale. A lid is included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review custom JGS1 quartz versions for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and fabrication details. Send a dimensioned drawing or labelled sketch, plus any holder or instrument information that affects fit. Modified designs and prototype batches are quoted separately from the listed SKU. Discuss your requirements.