(C022CS4) Glass Standard Cuvette, 2 mm Path, 700 µL
Original price was: $50.00.$45.00Current price is: $45.00.
C022CS4 is a glass standard cuvette for visible absorbance measurements with a 2 mm optical path, Two-Way Light geometry and 700 µL nominal capacity. Its open-top format supports direct filling, and the compact uncapped body can be useful where holder clearance is limited. MQ sells this item as a pack of four cuvettes.
Description
C022CS4 is a glass standard cuvette for visible absorbance work when you need a short 2 mm path in a compact open-top format. It combines straight-through Two-Way Light measurement with a 700 µL nominal capacity, so it suits routine filling by pipette while keeping the cell body small. MQ sells this item as a pack of four cuvettes.
The stated 350–2000 nm range places this cell in visible-range absorbance use rather than UV work. Its recorded external size of 4.5 × 12.5 × 45 mm applies to the uncapped cell body, which is the dimension set to use when checking holder space and surrounding clearance.
- Path Length
- 2 mm
- Sample Volume (Nominal)
- 700 µL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Standard Cuvette |
| Measurement Mode | Visible Absorbance Spectroscopy |
| Path Length | 2 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 350 nm |
| Wavelength Range — Upper Limit | 2000 nm |
| Sample Volume (Nominal) | 700 µL |
| External Dimensions | 4.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 4.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Glass |
| Closure Type | Lid |
| Closure Included | Yes |
| Fabrication Method | Molded 83 |
| Opening Configuration | Open Top |
Choose this option
Choose C022CS4 when your method needs a 2 mm optical path and a standard rectangular cell that is easy to fill from the top. The 700 µL nominal capacity gives you a practical planning figure for sample preparation, while the open top keeps loading, rinsing and emptying straightforward. This option is best suited to visible absorbance setups that use a straight beam through two opposing optical faces.
What makes this option different
- 2 mm optical path for methods that call for a shorter absorbance path than common longer-path cells.
- Open-top access for direct pipette filling, sample removal and rinsing without a threaded or plate-style closure.
- Two-Way Light layout for straight-through measurement across the main optical faces.
- 700 µL nominal capacity as a useful sample-planning figure for routine preparation and filling.
- Compact uncapped body at 4.5 × 12.5 × 45 mm for checking holder and compartment clearance.
- Molded 83 fabrication category with fused integrated construction noted in the source terminology, relevant when reviewing sample and cleaning conditions for this glass cell.
Using this cell
Fill the cell from the open top and make sure the liquid level covers the instrument beam during measurement. For absorbance work, keep the same orientation for blank and sample, and handle the cuvette by the non-optical outer surfaces to help keep the light path clean.
The 700 µL figure is a nominal capacity, not a stated minimum working volume. If your method uses a low fill level, check that the illuminated region remains fully covered in your own setup.
First-use check
- Inspect the cell for chips, cracks, residue or marks on the optical faces.
- Rinse with a cleaning method suitable for your sample and complete cell assembly.
- Place the cell in the holder and confirm that the beam passes through the intended optical faces at the required fill level.
Fit and optical alignment
The confirmed external dimensions apply to the uncapped cell body only. If you use the supplied closure in your own workflow, check top clearance separately because the recorded dimensions do not include any installed closure height.
Z Height is not specified for this SKU, so do not assume beam-height compatibility from body size alone where alignment is critical. Use the 4.5 × 12.5 × 45 mm body dimensions for physical clearance checks, then verify beam position in the holder or instrument.
Solvents and cleaning
This cell is listed under Molded 83. In practical use, that fabrication category is a useful starting point when considering sample type and cleaning approach, but the exact chemical limits of this complete glass cell assembly are not established here.
Rinse promptly after use, avoid abrasive cleaning methods, and do not let stubborn residues dry on the optical faces if they can be removed earlier. If your process involves aggressive reagents, unusual solvent exposure or demanding cleaning conditions, check suitability before regular use.
Included with this option
MQ sells this item as a pack of four glass standard cuvettes. A closure is included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch and identify the dimensions and tolerances that are critical to your application. Prototype batches typically involve 2–4 cells; the final quantity, feasibility, specifications, price and production time are confirmed in the project quotation. Modified designs and prototype batches are quoted separately from the listed SKU. Discuss your requirements and quote part number C022CS4.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.








Reviews
There are no reviews yet.