(C022CS3) Glass Standard Cuvette, 2 mm Path, 700 µL, Pack of 2
Original price was: $26.00.$24.00Current price is: $24.00.
C022CS3 is a glass standard cuvette for visible absorbance work with a 2 mm optical path, Two-Way Light layout and 700 µL nominal capacity. The open-top format gives direct pipette access, and this sales option is supplied as a pack of 2 cuvettes with closure included.
Description
C022CS3 is a glass standard cuvette for visible absorbance measurements when you need a short 2 mm optical path in a compact open-top format. Its 700 µL nominal capacity gives you a practical small-volume cell for routine work, and this option is sold as a pack of 2 cuvettes for buyers who want the same specification in a paired sale unit.
This cell is specified for 350–2000 nm use, so it is intended for visible-range absorbance methods rather than UV work. The Two-Way Light layout supports a straight-through reading path across the measurement faces.
- Path Length
- 2 mm
- Sample Volume (Nominal)
- 700 µL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Standard Cuvette |
| Measurement Mode | Visible Absorbance Spectroscopy |
| Pack Quantity | Pack of 2 |
| Path Length | 2 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 350 nm |
| Wavelength Range — Upper Limit | 2000 nm |
| Sample Volume (Nominal) | 700 µL |
| External Dimensions | 4.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 4.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Glass |
| Closure Type | Lid |
| Closure Included | Yes |
| Fabrication Method | Molded 83 |
| Opening Configuration | Open Top |
Choose this option
Choose C022CS3 when your method is set for a 2 mm path and you want the convenience of direct top filling in a compact glass cuvette. The open top simplifies loading and rinsing, while the pack-of-two sale unit suits labs that want matching cells of the same listed configuration for routine blank and sample handling or parallel preparation.
What makes this option different
- 2 mm optical path for methods that require a short absorbance path.
- Open-top access allows direct filling and cleaning from above.
- Two-Way Light configuration supports straight-through measurement geometry.
- 700 µL nominal capacity helps plan sample loading in a compact standard-cuvette body.
- Specified for 350–2000 nm for visible-range absorbance use.
- Pack of 2 cuvettes for the current MQ priced sale unit.
Using this cell
Fill each cell from the top and keep the liquid level high enough to cover the beam area during measurement. Remove visible bubbles before reading, and keep the same orientation for blank and sample runs so the same faces stay in the optical path.
The closure is useful as a cover after filling, but this listing does not establish a leak-tight or pressure-rated seal. The 700 µL value is a nominal capacity rather than a minimum working volume, so low-fill methods should be checked in the actual holder you use.
First-use check
Inspect both cuvettes before first use for chips, cracks or residue. Then test-fit the cell in your holder and run a blank with your normal solvent or buffer to confirm beam coverage and stable positioning.
Fit and optical alignment
The stated 4.5 × 12.5 × 45 mm dimensions apply to the uncapped cell body. Use them to check holder fit, side clearance and insertion space for the bare cuvette before relying on the covered setup.
Z Height is not established for this option, and the confirmed dimensions do not include the added height of any closure. Where beam-center height or top clearance is critical, fit should be checked in your own instrument rather than assumed from body size alone.
Solvents and cleaning
This cuvette is listed under Molded 83, and the source describes a fused integrated construction style for the glass body. Here, that fabrication category is most useful as a guide to sample and cleaning selection, not as a stand-alone guarantee of chemical compatibility for every condition.
Detailed chemical limits are not established here for the full cell and closure assembly. Use non-abrasive cleaning methods, avoid scratching the optical faces, and check suitability first if your samples or cleaning liquids involve aggressive chemistry or long contact time.
Included with this option
Sold as a pack of 2 glass cuvettes. Closure included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch and identify the dimensions and tolerances that are critical to your application. Prototype batches typically involve 2–4 cells; the final quantity, feasibility, specifications, price and production time are confirmed in the project quotation. Modified designs and prototype batches are quoted separately from the listed SKU. Discuss your requirements and quote part number C022CS3.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.








Reviews