Site Navigation

(MQQFC107) Quartz Counting Flow Cell, 0.2 mm path, Dual-Channel Layout

Weight50 g
SKU: MQQFC107

$509.00

In Stock

Dual-channel JGS1 quartz counting flow cell with a 0.2 mm optical path and four tube connections in two opposed pairs. The two channel levels are spaced 15 mm apart as drawn, with 1.5 mm OD / 1 mm ID tubes. The 75 × 25 × 4 mm body accommodates both measurement positions. One cell supplied.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQFC107 is a JGS1 quartz counting flow cell with a very short 0.2 mm optical path and a dual-channel layout. Its long rectangular body carries four tube connections arranged as two left-right pairs, making this option useful when you need two separate flow positions in one cell body rather than a single-channel inline format.

This design is built for UV/Vis work with a two-way light path. The 75 × 25 × 4 mm body gives you a plate-style optical section, while the four small tube connections let you route two separate channel positions through the same cell body.

Path Length
0.2 mm
Cell Type
Counting Flow Cell
Light Transmission Configuration
Two-Way Light

Selection Specifications

Product KindFlow Cell
Cell TypeCounting Flow Cell
Measurement ModeUV/Vis Spectroscopy
Path Length0.2 mm
Light Transmission ConfigurationTwo-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
External Dimensions75 × 25 × 4 mm
External Dimensions ScopeBody Only
MaterialQuartz
Material GradeJGS1
Port Count4
Tube Outer Diameter (OD)1.5 mm
Tube Inner Diameter (ID)1 mm
Fabrication MethodStandard 80
Port LayoutUpper channel, left end tube as drawn; Upper channel, right end tube as drawn; Lower channel, left end tube as drawn; Lower channel, right end tube as drawn
Pack Quantity1 Piece
Package Contents1 × Quartz Counting Flow Cell

Choose this option

Choose MQQFC107 when your setup needs a very short 0.2 mm path and two channel positions in one quartz flow cell. It is well suited to installations where the plumbing and holder are already planned around an upper and lower channel arrangement rather than one straight single-channel route.

What makes this option different

  • 0.2 mm optical path for methods built around a very short path length.
  • Dual-channel layout with two separate channel positions in one body.
  • Four tube connections arranged as two opposed pairs, one pair for each channel position.
  • 1.5 mm OD and 1 mm ID tube size for planning the connected tubing route.
  • 75 × 25 × 4 mm body-only format with additional space needed for tubing beyond the body.

Structure and dimensions

Product dimensions for checking holder clearance and sample access.
Product dimensions for checking holder clearance and sample access.Open image ↗

Using this cell

Plan the fluid route before installation so each left-right tube pair is connected to the intended channel position. Support the body during setup and avoid using the projecting tubes as handles or load points.

Fill slowly and inspect both optical regions for trapped bubbles before measurement. No nominal capacity is stated for this SKU, so fill level should be judged by complete coverage of the illuminated region in the channel you are using rather than by a fixed volume figure.

First-use check

  1. Inspect the optical faces and all four tube ends before connecting the cell.
  2. Confirm that the holder supports the body without twisting the tube connections.
  3. Run a blank through the intended channel path and verify alignment and bubble-free filling before sample work.

Fit and optical alignment

View the English selection reference.

The stated 75 × 25 × 4 mm dimensions describe the body only. Leave additional room for the four tube connections, attached tubing and bend radius on both ends of the cell.

Z Height is not stated for this item. If your holder or optical bench depends on a fixed beam center height, check that separately before ordering.

English selection reference
Selection reference ↗

Solvents and cleaning

This cell uses Standard 80 adhesive-bonded quartz construction. It suits routine room-temperature aqueous samples and buffers.

Avoid organic samples and organic cleaning solvents with this bonded assembly. Keep hydrofluoric acid away from quartz, avoid hot strong alkalis and abrasive cleaning methods, and clean the optical faces gently with non-abrasive optical tissue.

Included with this option

1 Quartz Counting Flow Cell.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We coordinate custom JGS1 quartz production for changes involving path length, channel layout, body size, tube arrangement, fabrication and related tolerances. Send your drawing or holder details, sample conditions, quantity and delivery destination through our contact page with SKU MQQFC107.

Additional information

Weight50 g

Reviews

There are no reviews yet.

Be the first to review “(MQQFC107) Quartz Counting Flow Cell, 0.2 mm path, Dual-Channel Layout”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar