MQQFC004 is a JGS1 quartz flow cell for UV/Vis measurements with a 10 mm optical path and 1 mL nominal capacity. It combines a compact optical body, Four-Way Light access and opposed fluid tubes, giving you a flow-cell format built around a familiar 10 mm path while keeping fluid connections at opposite ends.
This version also uses removable PTFE fittings and a Molded 83 fabrication. The body dimensions are 20 × 12.5 × 17 mm, and the internal chamber is shown as 10 × 10 × 12 mm, which is useful when you need to review both holder space and chamber geometry together.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 1 mL
- Opening Configuration
- Two Opposed Fluid Tubes
Selection Specifications
| Product Kind | Flow Cell |
|---|---|
| Cell Type | Flow Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 1 mL |
| Cell Body Dimensions | 20 × 12.5 × 17 mm |
| Internal Dimensions | 10 × 10 × 12 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Port Count | 2 |
| Tube Outer Diameter (OD) | 5 mm |
| Tube Inner Diameter (ID) | 2 mm |
| Fabrication Method | Molded 83 |
| Opening Configuration | Two Opposed Fluid Tubes |
| Fitting Material | PTFE |
| Detachable Fittings | Yes |
| Port Layout | End/side connection at the left in the referenced original; Opposite end/side connection at the right in the referenced original |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Flow Cell |
Choose this option
Choose this option when you need a 10 mm path in a compact flow-cell body and want fluid connections on opposite ends rather than an open-top chamber. It is a practical fit for UV/Vis systems where the optical path is familiar but the installation needs a smaller flow-through assembly with detachable PTFE connection parts.
What makes this option different
- 10 mm optical path in a flow-cell format for UV/Vis methods built around this standard path length.
- Four-Way Light configuration for setups that use optical access beyond a simple two-face transmission layout.
- Removable PTFE end fittings help you plan the connection arrangement around detachable connection parts.
- 5 mm OD / 2 mm ID opposed tubes and a 20 × 12.5 × 17 mm body support compact flow-cell installation planning.
Structure and dimensions

Using this cell
Install the cell with the fluid route planned in advance, then fill slowly so the sample chamber wets evenly and the beam region remains free of visible bubbles. Run blank and sample measurements under the same connection and flow conditions.
The nominal 1 mL figure describes the cell capacity, not a stated minimum working volume or full circuit exchange volume. Support the quartz body during handling, and do not use the fittings as handles when connecting or disconnecting the assembly.
First-use check
- Inspect the quartz body, optical faces and fitting areas before assembly.
- Check holder fit and beam alignment with a suitable blank.
- After connecting the fluid path, confirm stable filling and a bubble-free optical region.
Fit and optical alignment
View the English selection reference.
The body dimensions are 20 × 12.5 × 17 mm, and the opposed tube layout needs its own connection clearance beyond that body envelope. Check holder depth, beam position and the space needed for the fittings and attached tubing as separate parts of the installation.
Z Height is not established for this SKU, so instrument alignment should be verified from your holder geometry rather than assumed from body dimensions alone.

Solvents and cleaning
Molded 83 is generally chosen for methods where organic solvents may be relevant, but compatibility still depends on the complete wetted assembly, including the quartz body, PTFE fittings, connected tubing, concentration, temperature and contact time.
If your method involves aggressive chemicals or heated cleaning, please send the operating details for review before ordering. Keep hydrofluoric acid away from quartz, avoid hot strong alkalis and abrasive cleaners, and clean the optical faces with non-abrasive optical tissue.
Included with this option
1 Quartz Flow Cell. The listed price is for one piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review custom JGS1 quartz flow cells for changes to path length, chamber size, body envelope, connection dimensions, fabrication and tolerances. Send a drawing or labelled sketch together with holder details, sample conditions, quantity and target date.
Send a product-selection enquiry with SKU MQQFC004 and your tubing or holder requirements.
Additional information
| Weight | 50 g |
|---|
You must be logged in to post a review.












Reviews
There are no reviews yet.