MQQFC017 is a JGS1 quartz rectangular sample cell with Two-Way Light access and an open-at-both-ends body. Its source drawing marks two separate narrow gap regions, labelled 2 mm and 0.5 mm, for fixtures that align to a chosen measurement position rather than one uniform chamber layout. Sold as 1 piece.
Description
MQQFC017 is a JGS1 quartz rectangular sample cell for custom optical setups that use a slim open body and a selected beam position. The source drawing marks two separate narrow gap regions, labelled 2 mm and 0.5 mm, within the same cell body rather than one single uniform sample section. With a 35 × 5 × 42 mm outer size and Two-Way Light access, it suits fixtures that need a compact rectangular form and a defined transmission direction.
- Cell Type
- Rectangular Sample Cell
- Opening Configuration
- Open at Both Ends
Selection Specifications
| Product Kind | Specialized Cell |
|---|---|
| Cell Type | Rectangular Sample Cell |
| Measurement Mode | Transmission Spectroscopy |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| External Dimensions | 35 × 5 × 42 mm |
| Body Height | 42 mm |
| Base Dimensions | 35 × 5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Fabrication Method | Standard 80 |
| Opening Configuration | Open at Both Ends |
| Pack Quantity | 1 Piece |
Choose this option
Choose MQQFC017 when your setup is built around one of two distinct labelled sample regions in the same quartz body. The open-at-both-ends format gives direct access for filling and for custom end support, while the slim 5 mm body thickness can help where holder clearance is limited. This option is most useful when your fixture already defines how the cell is retained and where the beam will pass.
What makes this option different
- Two labelled narrow regions in one body: the drawing identifies separate 2 mm and 0.5 mm gap positions, so beam placement matters and the exact optical section depends on how the cell is arranged in your fixture.
- Open at both ends: you have direct access for filling, rinsing and inspection, but sample retention and any sealing must come from your own holder or end arrangement.
- Two-Way Light layout: this cell is arranged for transmission through the specified optical direction, not side-access measurement geometry.
- Slim rectangular envelope: the 35 × 5 × 42 mm body is easy to place in narrow rectangular clamps or custom mounts where thickness is restricted.
- Adhesive-bonded quartz construction: the supplier identifies this as an adhesive-bonded assembly, which is a practical choice for routine room-temperature aqueous and buffer-based work.
- JGS1 quartz material: listed for 200–2500 nm material range, useful when your method requires quartz rather than glass.
Using this cell
Set the cell in a holder that keeps one chosen labelled region in the beam path, and keep that orientation the same for blank and sample measurements. Because the two marked gaps are separate positions in the body, do not treat them as one interchangeable uniform chamber.
The open ends make manual filling and rinsing straightforward, but they also mean the cell itself does not provide a built-in closure. Plan how the sample will be introduced, retained and supported before routine use, especially if the cell will be mounted vertically or handled outside a bench fixture.
First-use check
- Inspect the optical faces and both open ends for chips, residue or handling marks.
- Place the cell in the holder and verify that the beam passes through the intended labelled region without clipping.
- Test your filling and retention method with a blank solution before introducing sample.
Fit and optical alignment
Check clearance against the full 35 × 5 × 42 mm outer dimensions. The slim body can fit compact holders, but the mount should support the cell evenly and avoid concentrated force at the end edges or across the optical faces.
Z Height is not specified for this cell. If your instrument or holder needs a defined beam-center height, verify the mounted beam position in the actual assembly rather than assuming alignment from the outer size alone.

Solvents and cleaning
This cell uses Standard 80 adhesive-bonded quartz construction. It is generally suited to routine room-temperature aqueous samples and buffers. Avoid organic samples and organic cleaning solvents on the bonded assembly.
Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaning methods. Clean gently with a suitable lint-free, non-abrasive wipe.
Included with this option
1 MQQFC017 rectangular sample cell. The listed price is for one cell.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz versions for changes to the labelled gap layout, outer dimensions, openings and holder-related geometry. If you need a different body format or a layout matched to your fixture, send a labelled sketch or drawing with the critical dimensions and sample conditions.
Send a product-selection enquiry with SKU MQQFC017 and your holder or layout details.