(MQQFC124) JGS1 Quartz Flow Cell, 2 mm Path, 45 µL, Opposed Tubes
Description
MQQFC124 is a compact JGS1 quartz flow cell for UV/Vis work with a 2 mm optical path and 45 µL nominal capacity. Its small body, Two-Way Light layout and opposed tube connections make it a practical choice when you need a short-path flow cell that fits into a tightly planned optical and tubing assembly.
The cell uses Standard 80 adhesive-bonded quartz construction. The optical body, full fixed-parts envelope and tube sizes are stated separately, which helps you check holder space, beam access and tubing approach as separate parts of the installation.
- Path Length
- 2 mm
- Sample Volume (Nominal)
- 45 µL
- Opening Configuration
- Two Opposed Fluid Tubes
Selection Specifications
| Product Kind | Flow Cell |
|---|---|
| Cell Type | Counting Flow Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 2 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 45 µL |
| External Dimensions | 30 × 6 × 10 mm |
| Cell Body Dimensions | 18 × 6 × 10 mm |
| Uncapped Cell Dimensions | 30 × 6 × 10 mm |
| External Dimensions Scope | Uncapped Cell |
| Internal Dimensions | 2 × 5 × 6 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Port Count | 2 |
| Tube Outer Diameter (OD) | 3 mm |
| Tube Inner Diameter (ID) | 1 mm |
| Fabrication Method | Standard 80 |
| Opening Configuration | Two Opposed Fluid Tubes |
| Port Layout | End/side connection at the left in the referenced original; Opposite end/side connection at the right in the referenced original |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Flow Cell |
Choose this option
Choose this option when your setup needs a 2 mm flow path in a compact quartz cell with direct tube connections on opposite ends. It is particularly useful where the outer envelope matters as much as the optical path, because the body size, overall fixed length and tube dimensions are all part of the selection decision.
What makes this option different
- 2 mm optical path with 45 µL nominal capacity for short-path UV/Vis flow measurements.
- Two opposed fluid tubes with 3 mm OD and 1 mm ID for connection planning on both ends.
- Compact 30 × 6 × 10 mm fixed-parts envelope with an 18 × 6 × 10 mm optical body.
- Two-Way Light layout for a straight optical path through the cell.
Structure and dimensions

Using this cell
Install the cell so the optical faces align with the beam and support the body during tubing connection. Fill and flush slowly enough to clear bubbles from the optical region before running a blank or sample, so the short transmission region is filled with liquid throughout the measurement.
The 45 µL figure is the nominal capacity of the cell. It is not a stated minimum working volume, so your priming and flushing routine should be set by the complete liquid circuit and the way your system fills the sample region.
First-use check
- Inspect the optical faces, bonded areas and tube openings before installation.
- Flush with a suitable liquid for your method and confirm bubble-free filling in the optical region.
- Check holder fit and run a blank under the same flow conditions planned for the sample.
Fit and optical alignment
View the English selection reference. Also available in the product gallery.
The uncapped cell envelope is 30 × 6 × 10 mm, while the optical body itself is 18 × 6 × 10 mm. Leave additional space for tubing approach, connector clearance and bend radius on both ends.
Z Height is not stated here, so outer dimensions alone should not be treated as proof of instrument compatibility. If your holder has a fixed beam position, check that beam line against your current cell or fixture before ordering.

Solvents and cleaning
Standard 80 is an adhesive-bonded quartz construction commonly used for room-temperature aqueous samples and buffers. Avoid organic samples and organic cleaning solvents with this bonded assembly. If your method requires organic solvents or heated operation, ask about a suitable Sintered or Molded alternative before ordering.
Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaning materials. Clean the optical faces gently with non-abrasive optical tissue.
Included with this option
1 MQQFC124 flow cell. The listed price is for one cell.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz flow cells for changes to path length, body size, tube layout, capacity and related dimensional requirements. Send your drawing or labelled sketch, critical dimensions, liquid conditions and target quantity for review.
Send a product-selection enquiry with SKU MQQFC124, your holder details, tubing layout, sample conditions and delivery destination.
Additional information
| Weight | 50 g |
|---|
You must be logged in to post a review.