(MQQFC132) Quartz Flow Cell, 3.6 mm path, 2.7 mL nominal capacity, Two Top Access Holes
$408.00
MQQFC132 is a JGS1 quartz flow cell with a 3.6 mm optical path, Two-Way Light layout and 2.7 mL nominal capacity for UV/Vis work. Two top access holes and a 31 × 3.6 × 31 mm internal chamber make it suitable when you want direct access from above for filling, rinsing or connection planning. The listed price is for 1 piece.
Description
MQQFC132 is a JGS1 quartz flow cell for UV/Vis spectroscopy, built around a 3.6 mm optical path and a 2.7 mL nominal capacity. Its two top access holes and broad internal chamber make it easier to plan top-side filling or line access while keeping a defined transmission path through the sample.
- Path Length
- 3.6 mm
- Sample Volume (Nominal)
- 2.7 mL
- Opening Configuration
- Two Top Access Holes
Selection Specifications
| Product Kind | Flow Cell |
|---|---|
| Cell Type | Flow Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 3.6 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 2.7 mL |
| External Dimensions | 40 × 12.6 × 40 mm |
| Body Height | 40 mm |
| Base Dimensions | 40 × 12.6 mm |
| Internal Dimensions | 31 × 3.6 × 31 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Port Count | 2 |
| Opening Configuration | Two Top Access Holes |
| Port Layout | Access hole at the left of the top face as drawn; Access hole at the right of the top face as drawn |
| Wall Thickness | 4.5 mm |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Flow Cell |
Choose this option
Choose MQQFC132 when you need a short optical path in a larger quartz flow cell that is accessed from the top rather than through end fittings. The two-hole top layout is useful when your setup benefits from direct filling, rinsing or visual observation during loading, and the 31 × 3.6 × 31 mm internal chamber gives you a clear chamber shape to work around when planning the sample route.
What makes this option different
- 3.6 mm optical path: suited to methods that need a defined short transmission distance through the sample.
- Two top access holes: supports top-entry filling or connection planning without relying on opposed end ports.
- 2.7 mL nominal capacity: pairs the short path with a relatively broad sample chamber.
- 40 × 12.6 × 40 mm body: gives a compact square form for holder and compartment clearance checks.
Using this cell
Fill or connect the cell through the two top openings, introducing liquid slowly so the chamber fills evenly. This top-access layout can make it easier to watch the sample region during loading and remove visible bubbles before measurement.
Use a blank under the same filled condition as the sample, and keep the exterior optical faces clean and dry. The stated 2.7 mL is the nominal cell capacity, not a minimum working volume.
No pressure limit is stated for this SKU. If your setup is pressurized, check the operating conditions and connection method before use.
First-use check
- Inspect the optical faces, chamber and top openings for chips, residue or handling marks.
- Seat the cell in the holder and confirm that the beam crosses the intended optical path.
- Fill with a suitable blank, clear visible bubbles, and repeat the blank after the cell is fully positioned.
Fit and optical alignment
View the English selection reference.
The body measures 40 × 12.6 × 40 mm. The top holes are shown with a 3.5 mm diameter and 20 mm centre spacing, so check both body fit and the clearance above the top face for syringes, tubing or other loading tools.
Z Height is not specified for this cell. If your instrument uses a fixed beam height, verify that the beam passes through the intended sample region before ordering rather than assuming alignment from the outer body size alone.

Solvents and cleaning
This cell uses quartz, but the fabrication grade for MQ cuvette classification is not established for this SKU. For background on MQ fabrication categories, see Fabrication Method of Cuvettes.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and clean optical faces gently with suitable non-abrasive materials. If your method involves demanding solvent exposure or extended contact time, review the full liquid conditions of the assembly before use.
Included with this option
1 Quartz Flow Cell. The listed price is for one piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz projects for changes involving dimensions, optical path length, sample volume, optical windows or Z Height, interfaces and tolerance requirements. Prototype batches typically involve 2–4 cells, with feasibility, final specifications, quantity, price and production time confirmed in the project quotation.
Send a product-selection enquiry with SKU MQQFC132, your holder or drawing details, sample conditions, quantity and destination.
Additional information
| Weight | 50 g |
|---|
You must be logged in to post a review.










Reviews
There are no reviews yet.