Site Navigation

(MQQFL020) Quartz Flow Cell, 10 mm path, 5.8 mL nominal capacity, Long Sample Chamber

Weight150 g
SKU: MQQFL020

$599.00

In Stock

MQQFL020 is a JGS1 quartz flow cell with a 10 mm optical path, 5.8 mL nominal capacity and a long sample chamber. It combines Two-Way Light geometry with one fixed 4 mm OD / 2 mm ID tube at one end and an open end at the other. Sold as 1 piece.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQFL020 is a JGS1 quartz flow cell with a 10 mm optical path and 5.8 mL nominal capacity. Its long sample chamber, one-tube-plus-open-end layout and 79 × 12.5 × 12.5 mm uncapped envelope make it suitable where you want direct access to the sample region as well as a fixed tube connection on one side.

Path Length
10 mm
Sample Volume (Nominal)
5.8 mL
Opening Configuration
One Fluid Tube and One Open End

Selection Specifications

Product KindFlow Cell
Cell TypeFlow Cell
Measurement ModeUV/Vis Spectroscopy
Path Length10 mm
Light Transmission ConfigurationTwo-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)5.8 mL
External Dimensions79 × 12.5 × 12.5 mm
Uncapped Cell Dimensions79 × 12.5 × 12.5 mm
External Dimensions ScopeUncapped Cell
MaterialQuartz
Material GradeJGS1
Port Count1
Tube Outer Diameter (OD)4 mm
Tube Inner Diameter (ID)2 mm
Fabrication MethodMolded 83
Opening ConfigurationOne Fluid Tube and One Open End
Port LayoutSingle fixed tube at the left axial end in the referenced original
Wall Thickness1.25 mm
Pack Quantity1 Piece
Package Contents1 × Quartz Flow Cell

Choose this option

Choose this cell when your method benefits from a larger nominal volume than a compact flow cell and the open-end access suits how you fill, drain or inspect the sample region. The single fixed tube provides one defined connection point, while the opposite open end leaves the chamber accessible for handling that would be awkward in a fully closed two-port body.

What makes this option different

  • 5.8 mL nominal capacity with a 10 mm optical path in a long sample chamber.
  • One fixed tube and one open end for a different loading and connection layout from closed two-port cells.
  • Fixed tube size of 4 mm OD / 2 mm ID for planning external connection hardware.
  • Molded 83 JGS1 quartz construction with Two-Way Light geometry for UV/Vis use.

Structure and dimensions

Product dimensions for checking holder clearance and sample access.
Product dimensions for checking holder clearance and sample access.Open image ↗

Using this cell

Support the cell body during handling and installation, and do not use the fixed tube as a handle. Because this version has one open end, fill and drain it in a way that keeps the optical region covered and free of trapped bubbles before taking a blank or sample reading.

The 5.8 mL figure is the nominal capacity, not a stated minimum working volume. If your method runs close to the lowest practical fill level, check that your actual fill in the intended mounting position keeps the beam path covered consistently.

First-use check

  1. Inspect the optical faces, the open end and the fixed tube connection for particles or handling residue.
  2. Test the fit in your holder and run a blank with the cell in its intended measuring position.
  3. Fill slowly and verify that the illuminated region is fully wetted and free of bubbles.

Fit and optical alignment

View the English selection reference.

The fixed-parts envelope is 79 × 12.5 × 12.5 mm, excluding separately attached flexible tubing and removable caps. Check holder length, side clearance and access to the open end separately from the optical body fit.

Z Height is not established for this SKU, so do not assume beam-center compatibility from the overall dimensions alone. If your instrument or holder requires a defined beam height, that point should be checked before ordering.

English selection reference
Selection reference ↗

Solvents and cleaning

Molded 83 is commonly chosen for methods involving organic solvents and temperature-related applications, but suitability still depends on the complete assembly and the actual liquid conditions. The source also describes this construction as acid- and alkali-resistant in general terms, but specific chemical limits are not established here.

Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaning materials, and clean the optical faces gently with non-abrasive optical tissue. For aggressive chemicals, elevated temperature or long contact times, please review the full liquid conditions before use.

Included with this option

1 Quartz Flow Cell. The listed price is for one piece.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We coordinate custom JGS1 quartz projects for changes to path length, chamber size, overall dimensions, openings and connections. Send a drawing or labelled sketch together with holder details, sample conditions and quantity through the contact page if you need a different geometry from the listed SKU.

Additional information

Weight150 g

Reviews

There are no reviews yet.

Be the first to review “(MQQFL020) Quartz Flow Cell, 10 mm path, 5.8 mL nominal capacity, Long Sample Chamber”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare