(MQQFL057) Quartz Screw-Top Cuvette, 10 mm path, Valve Closure Assembly, Pack of 2
$720.00
MQQFL057 is a JGS1 quartz screw-top cuvette with a 10 mm optical path, five-way optical access and a valve closure assembly. Its 3.5 mL nominal capacity and M10 top thread suit UV/Vis and fluorescence setups that need enclosed sample access from above and optical access from multiple sides. Supplied as a pack of 2 with accompanying closures.
Description
MQQFL057 is a JGS1 quartz screw-top cuvette supplied as a pack of 2. Each cell combines a 10 mm optical path, a 3.5 mL nominal capacity and five-way optical access with a valve closure assembly, giving you a quartz measurement cell with top-controlled sample access and added side access around the sample region. This is a practical choice when you need two cells of the same listed geometry for paired work or repeated measurement routines.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 3.5 mL
- Closure Type
- Valve Closure Assembly
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Screw-Top Cuvette |
| Measurement Mode | Fluorescence Spectroscopy; UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Five-Sided Optical Windows |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 3.5 mL |
| Cell Body Dimensions | 12.5 × 12.5 × 35 mm |
| Overall Height without Closure | 64 mm |
| Body Height | 35 mm |
| Overall Height with Closure | 81 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Valve Closure Assembly |
| Closure Included | Yes |
| Port Thread | M10 |
| Fabrication Method | Molded 83 |
| Sales Unit | pack of 2 |
| Package Contents | 2 × Quartz Screw-Top Cuvette; Accompanying closures |
Choose this option
Choose MQQFL057 when you need the 10 mm valve-top version in a two-cell sales pack rather than a single piece. It suits UV/Vis and fluorescence setups where the sample is handled through the top assembly and the measurement layout uses more than the two main transmission faces.
What makes this option different
- Pack of 2 complete cuvettes in the listed configuration.
- 10 mm optical path with 3.5 mL nominal capacity per cell.
- Five-way optical access for setups that use additional optical faces around the sample region.
- Valve closure assembly with M10 threaded top connection for controlled filling or handling from above.
Using this cell
Fill the cell so the sample covers the illuminated region, then remove bubbles before measurement. When operating the valve closure, support the cell body and avoid using the holder as the only support point for the top assembly.
The nominal volume is 3.5 mL per cell. It should not be treated as a minimum working volume, so low-fill methods and fixed beam-height methods should be checked against your own setup before purchase.
First-use check
- Inspect both cells for clean optical faces, intact edges and a clear sample chamber.
- Test holder fit and top clearance before introducing sample.
- Run a blank in the intended orientation, then repeat after filling to confirm stable alignment and bubble-free loading.
Fit and optical alignment
View the English selection reference. Also available in the product gallery.
Each cell has a 12.5 × 12.5 mm base, a 35 mm body height and an 81 mm overall height with the closure fitted. Check not only the holder slot, but also the vertical clearance needed for the neck, valve area and hand access above the instrument or fixture.
The five-way optical layout describes the available optical access, not automatic compatibility with a particular instrument. Keep the same orientation for blank and sample work, and make sure the holder does not block any side your measurement geometry requires. Z Height is not specified for this SKU.

Solvents and cleaning
Molded 83 quartz is commonly selected for methods that may involve organic solvents or elevated temperatures, but the exact liquid compatibility of the full assembly still depends on the complete cell and closure. For aggressive chemicals, heated conditions or long contact times, please check the intended conditions before use.
Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaning methods. Clean the optical faces gently with non-abrasive tissue and a suitable cleaning liquid for your process.
Included with this option
2 Quartz Screw-Top Cuvettes with accompanying closures. The listed price is for one pack of 2.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closure details and tolerances. If you need a modified version, please send your drawing or holder information and sample conditions through our contact page.
Additional information
| Weight | 150 g |
|---|
You must be logged in to post a review.