(MQQMC024) Quartz Flow Cell, 10 mm path, 32 µL nominal capacity, 2 mm Optical Opening

Weight50 g
SKU: MQQMC024

$179.00

In Stock

Quartz flow cell for UV/Vis measurements with a 10 mm optical path, 32 µL nominal capacity and two top fluid connections with stainless steel fittings. Its stated 8.5 mm Z Height helps when beam position must match the holder, and the listed price is for 1 piece.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQMC024 is a JGS1 quartz flow cell with a 10 mm optical path, 32 µL nominal capacity and two top fluid connections. It suits UV/Vis setups that need the familiar 10 mm path in a compact flow format, and the stated 8.5 mm Z Height gives a direct reference for checking beam position in a holder or instrument.

Path Length
10 mm
Sample Volume (Nominal)
32 µL
Opening Configuration
Two Top Fluid Connections

Selection Specifications

Product KindFlow Cell
Cell TypeFlow Cell
Measurement ModeUV/Vis Spectroscopy
Path Length10 mm
Light Transmission ConfigurationTwo-Way Light
Z Height8.5 mm
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)32 µL
External Dimensions12.5 × 12.5 × 35 mm
Body Height35 mm
Base Dimensions12.5 × 12.5 mm
MaterialQuartz
Material GradeJGS1
Port Count2
Fabrication MethodStandard 80
Opening ConfigurationTwo Top Fluid Connections
Fitting MaterialStainless Steel
Port LayoutTop connection at the left in the referenced original; Top connection at the right in the referenced original
Pack Quantity1 Piece
Package Contents1 × Quartz Flow Cell

Choose this option

Choose this cell when you want a 10 mm flow path in a compact body and prefer tubing access from above the cell. Its 32 µL nominal capacity and 8.5 mm Z Height are especially useful when you need to plan both a small internal volume and a defined beam-center position without moving to a larger body.

What makes this option different

  • 10 mm optical path for UV/Vis methods built around the standard cuvette transmission length.
  • 32 µL nominal capacity in a compact flow-cell body.
  • 8.5 mm Z Height to help check beam-center alignment against your holder or instrument.
  • Two top fluid connections with stainless steel fittings for above-body tubing access.

Structure and dimensions

Product structure and the listed configuration.
Product structure and the listed configuration.Open image ↗

Using this cell

Mount the cell so the optical faces sit correctly in the beam, then connect the fluid lines from the top with the body fully supported. Fill gradually and watch the sample region for trapped bubbles before taking a blank or sample reading.

The stated 32 µL value is the nominal cell volume, not a minimum working volume. In practice, your operating fill should be enough to cover the optical region under the actual flow conditions in your system.

First-use check

  1. Inspect the optical faces, body edges and fitted connection points before use.
  2. Verify holder fit and beam alignment with a suitable blank.
  3. After connection and filling, confirm that the optical region is bubble-free and that the exterior faces are clean and dry.

Fit and optical alignment

View the English selection reference. Also available in the product gallery.

The bare body dimensions are 12.5 × 12.5 × 35 mm. Check holder depth and surrounding clearance separately from the added space required for the top fittings, tubing and bend radius.

The 8.5 mm Z Height is useful for matching the beam center, but instrument fit still depends on your holder, clamp and connection clearance. The fittings are stainless steel, but the exact fitting grade and pressure limit are not stated for this SKU.

English selection reference
Selection reference ↗

Solvents and cleaning

Standard 80 is an adhesive-bonded quartz construction generally used for room-temperature water-based samples and buffer solutions. Avoid organic samples and organic cleaning solvents with this construction.

Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaners, and clean the optical faces gently with suitable non-abrasive lab wipes or optical tissue. For the full assembly, also consider the suitability of the stainless steel fittings for your process fluid and cleaning routine.

Included with this option

1 quartz flow cell, sold as 1 piece.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We coordinate custom JGS1 quartz projects for changes to path length, Z Height, body size, volume, connection layout and related tolerances. Send a drawing or labelled sketch together with holder details, sample conditions and the dimensions that matter most in your setup through the contact page, and mention SKU MQQMC024.

Additional information

Weight50 g

Reviews

There are no reviews yet.

Be the first to review “(MQQMC024) Quartz Flow Cell, 10 mm path, 32 µL nominal capacity, 2 mm Optical Opening”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare